Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5017N56 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5017N56: | TS5017N56 |
---|---|---|---|
Japan: | Japan | Material: | Iron |
Color: | Black | Temperature: | 20-80 |
Wire: | Wire | Dimension: | 50mm |
TS3103N156
TS5017N56
TS3667N2E6
TS3667N3E7
TS3667N3E8
TS3667N11E1
TS3667N11E2
TS3667N12E4
TS3667N11E3
TS3667N12E5
TS3667N12E6
TS3667N31E7
TS3667N13E8
TS3624N1E1
TS3624N1E2
TS3624N2E3
TS3624N2E4
TS3624N3E5
TS3624N3E6
TS3630N1E1
TS3630N1E2
TS3630N2E3
TS3630N2E4
TS3630N3E5
To back up a user program and save it without loss in the event of a power failure. |
BATT. socket on the CPU (see Reference Manual, CPU Data Section 1.2). You can also back up modules in an expansion rack via the EXT. |
For retentive storage of bit memory, timers, counters, and system data as well as data in variable data blocks. |
BATT socket on the receive IM. Inserting a Backup Battery |
You can also provide this backup with an external battery (5 to 15 VDC). You achieve this by connecting the external battery to the EXT |
o insert the backup battery (batteries) in the power supply module, proceed as
follows:
1. Discharge any static charge by touching a grounded metal part of the .
2. Open the cover of the power supply module.
3. Insert the backup battery/batteries in the battery compartment.
Ensure correct polarity of the battery.
4. Switch on battery monitoring with the BATT INDIC slide switch, as shown in the
following table.
have a single-width power supply module, set the BATT INDIC switch to BATT.
have a double or triple-width power supply
module and want to monitor
a backup battery,
set the BATT INDIC switch to 1BATT.
have a double or triple-width power supply
module and want to monitor both backup
batteries,Hazardous to persons and property, risk of pollutant emission.
A lithium battery can explode if treated incorrectly; improper disposal of old lithium
batteries can result in pollutant emission. The following instructions should
therefore be observed without fail:
• Do not throw new or discharged batteries into a fire and do not solder onto the
cell body (max. temperature 100° C). Do not recharge, there is a risk of
explosion. Do not open the battery, and only replace it with one of the same
type. Obtain the replacement via (see the Reference Manual, Module
specifications appendix C for the order number). This will ensure that you have
a short-circuit protected type.
• Old batteries should be disposed of with battery manufacturers/recyclers if
possible, or as hazardous wasteLithium batteries (lithium/thionyl chloride) are used as backup batteries for the
. In lithium batteries of this technology, a passivation layer can develop after
storage for a very long time, and the immediate functional capability of the battery
may not be certain. This may result in an error message when the power supply
module is switched on.
The power supply modules of the are capable of reducing the passivation
layer of the lithium battery with a defined load on the battery. This process may
take some minutes. When the passivation layer has been reduced and the lithium
battery has reached its rated voltage, the error message of the power supply
module can be acknowledged with the FMR button.
Since the storage time of the lithium battery is not usually known, we recommend
the following procedure:
• Insert the backup battery/batteries in the battery compartment.
• Acknowledge any battery error message of the power supply module with the
FMR button.