    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS5017N56

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    Tamagawa: Tamagawa TS5017N56: TS5017N56
    Japan: Japan Material: Iron
    Color: Black Temperature: 20-80
    Wire: Wire Dimension: 50mm

     

     

    TS3103N156

    TS5017N56

    TS3667N2E6

    TS3667N3E7

    TS3667N3E8

    TS3667N11E1

    TS3667N11E2

    TS3667N12E4

    TS3667N11E3

    TS3667N12E5

    TS3667N12E6

    TS3667N31E7

    TS3667N13E8

    TS3624N1E1

    TS3624N1E2

    TS3624N2E3

    TS3624N2E4

    TS3624N3E5

    TS3624N3E6

    TS3630N1E1

    TS3630N1E2

    TS3630N2E3

    TS3630N2E4

    TS3630N3E5

     

     

    TAMAGAWA TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56TAMAGAWA TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56TAMAGAWA TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56TAMAGAWA TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56 TS5017N56

    To back up a user program and save it without loss in the event of a power
    failure.
    BATT. socket on the
    CPU (see Reference Manual, CPU Data Section 1.2). You can also back up
    modules in an expansion rack via the EXT. 
    For retentive storage of bit memory, timers, counters, and system data as well
    as data in variable data blocks.
    BATT socket on the receive IM.
    Inserting a Backup Battery
    You can also provide this backup with an external battery (5 to 15 VDC). You
    achieve this by connecting the external battery to the EXT
     

    o insert the backup battery (batteries) in the power supply module, proceed as
    follows:
    1. Discharge any static charge by touching a grounded metal part of the .
    2. Open the cover of the power supply module.
    3. Insert the backup battery/batteries in the battery compartment.
    Ensure correct polarity of the battery.
    4. Switch on battery monitoring with the BATT INDIC slide switch, as shown in the
    following table.
    have a single-width power supply module, set the BATT INDIC switch to BATT.
    have a double or triple-width power supply
    module and want to monitor
    a backup battery,
    set the BATT INDIC switch to 1BATT.
    have a double or triple-width power supply
    module and want to monitor both backup
    batteries,Hazardous to persons and property, risk of pollutant emission.
    A lithium battery can explode if treated incorrectly; improper disposal of old lithium
    batteries can result in pollutant emission. The following instructions should
    therefore be observed without fail:
    • Do not throw new or discharged batteries into a fire and do not solder onto the
    cell body (max. temperature 100° C). Do not recharge, there is a risk of
    explosion. Do not open the battery, and only replace it with one of the same
    type. Obtain the replacement via (see the Reference Manual, Module
    specifications appendix C for the order number). This will ensure that you have
    a short-circuit protected type.
    • Old batteries should be disposed of with battery manufacturers/recyclers if
    possible, or as hazardous wasteLithium batteries (lithium/thionyl chloride) are used as backup batteries for the
    . In lithium batteries of this technology, a passivation layer can develop after
    storage for a very long time, and the immediate functional capability of the battery
    may not be certain. This may result in an error message when the power supply
    module is switched on.
    The power supply modules of the are capable of reducing the passivation
    layer of the lithium battery with a defined load on the battery. This process may
    take some minutes. When the passivation layer has been reduced and the lithium
    battery has reached its rated voltage, the error message of the power supply
    module can be acknowledged with the FMR button.
    Since the storage time of the lithium battery is not usually known, we recommend
    the following procedure:
    • Insert the backup battery/batteries in the battery compartment.
    • Acknowledge any battery error message of the power supply module with the
    FMR button.

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099