Home ProductsTAMAGAWA

TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616

TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616

    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
    • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616
  • TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616

    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS5305N616

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    TAMAGAWA: TAMAGAWA TS5305N616: TS5305N616
    Japan: Japan Color: Black
    Material: Iron Temperature: 20-90
    WIRE: Wire Dimension: 80mm

    TS5305N616

     TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616TAMAGAWA TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616 TS5305N616

    each
    submodule is dependent on the IO system. For PROFINET IO, for example, this data width
     
    s 1024 bytes.By means of process image partitions, the CPU synchronizes the updated inputs/outputs of  
    particular modules with defined user program sections.  

    Please contact with “Tommy” for the price

    TS3684N11E3

    TS3684N12E6

    TS3684N13E8

    TS3617N1E3

    TS3617N1E1

    TS3617N1E2

    TS3617N2E4

    TS3617N2E5

    TS3617N2E6

    TS3617N2E7

    TS3617N3E8

    TS3617N3E9

    TS3617N3E1

    TS3617N11E3

    TS3617N11E1

    TS3617N11E2

    TS3617N12E4

    TS3617N12E5

    TS3617N12E6

    TS3617N12E7

    TS3617N13E8

    TS3617N13E9

    TS3617N13E1

    TS3653N1E1

    TS3653N1E2

    TS3653N1E3

    TS3653N2E4

    TS3653N2E5

    TS3653N2E6

    TS3653N3E7

    TS3653N3E8

    TS3653N3E9

    TS3653N11E1

    TS3653N11E2

    TS3653N11E3

     

    In the automation system, the overall process image is subdivided into up to 32
    process image partitions (PIP).
    The CPU automatically updates PIP 0 (automatic update) in each program cycle and assigns
    it to OB 1.
    You can assign the process image partitions PIP 1 to PIP 31 to the other OBs during
    configuration of the input/output modules.
    After the OB has been started, the CPU updates the assigned process image partition for
    inputs and reads in the process signals. At the end of the OB, the CPU writes the outputs of
    the assigned process image partition directly to the peripheral outputs by the system without
    having to wait for the completion of the cyclic program processing.As an alternative to methods already described, you can use the instruction "UPDAT_PI" or
    the instruction "UPDAT_PO" at the start or the at the end of the respectively assigned OB to
    update the process image. In STEP 7, these instructions are available on the "Instructions"
    Task Card under "Extended instructions" and may be called from any point in the program.
    Requirements for updating process image partitions with the "UPDAT_PI" and "UPDAT_PO"
    instructions:
    ● The process image partitions cannot be assigned to any OB, i.e. they cannot be
    automatically updatedPPI 0 (automatic update) cannot be updated with the "UPDAT_PI" and "UPDAT_PO"
    instructions.With this instruction you read the sigWith this instruction you transmit the process image partition of the outputs to the output
    modulesIn the isochronous mode interrupt OBs you use the instructions "SYNC_PI" and "SYNC_PO"
    to update the process image partitions. Additional information on isochronous mode interrupt
    OBs is available in the STEP 7 online help.You also have direct read and write access to the I/O, as an alternative to access via the
    process image, should direct access be required for programming reasons. A direct (write)
    I/O access also writes the process image. This prevents the situation where a subsequent
    output of the process image overwrites the value written via direct access again.Additional information on process image partitions is available found in the function manual,
    Cycle and response timesYou configure and assign parameters to the ET 200MP (interface module and I/O modules)
    with STEP 7 or in the configuration software of another manufacturerYou can find an overview of the most important documents and links for the TIA Portal in the
    following FAQ on the Internet The PROFIsafe address is saved permanently on the electronic coding element of the
    /ET 200MP fail-safe modules. You can find additional information on the electronic
    coding element in the section Replacing the coding element at the power connector of the
    system power supply and load current supply (Page 285).
    Note
    The supply voltage L+ must be applied to the F-module during the assignment of the
    PROFIsafe address (F-destination address together with F-source addressFor additional information on assigning the PROFIsafe address (F-destination address
    together with the F-source address), refer to the SIMATIC Safety - Configuring and
    ProgramminThe occurrence of a trigger results in the following reaction:
    ● If the event comes from an event source to which you have assigned an OB, this

    Contact Details
    Guang Zhou Lai Jie Electric Co.,Ltd

    Contact Person: Mr. Tommy

    Tel: 86-020-87268766

    Fax: 86-020-87269099

    Send your inquiry directly to us (0 / 3000)