Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5305N616 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5305N616: | TS5305N616 |
---|---|---|---|
Japan: | Japan | Color: | Black |
Material: | Iron | Temperature: | 20-90 |
WIRE: | Wire | Dimension: | 80mm |
TS5305N616
each submodule is dependent on the IO system. For PROFINET IO, for example, this data width |
|
s 1024 bytes.By means of process image partitions, the CPU synchronizes the updated inputs/outputs of | |
particular modules with defined user program sections. |
Please contact with “Tommy” for the price
TS3684N11E3
TS3684N12E6
TS3684N13E8
TS3617N1E3
TS3617N1E1
TS3617N1E2
TS3617N2E4
TS3617N2E5
TS3617N2E6
TS3617N2E7
TS3617N3E8
TS3617N3E9
TS3617N3E1
TS3617N11E3
TS3617N11E1
TS3617N11E2
TS3617N12E4
TS3617N12E5
TS3617N12E6
TS3617N12E7
TS3617N13E8
TS3617N13E9
TS3617N13E1
TS3653N1E1
TS3653N1E2
TS3653N1E3
TS3653N2E4
TS3653N2E5
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS3653N11E1
TS3653N11E2
TS3653N11E3
In the automation system, the overall process image is subdivided into up to 32
process image partitions (PIP).
The CPU automatically updates PIP 0 (automatic update) in each program cycle and assigns
it to OB 1.
You can assign the process image partitions PIP 1 to PIP 31 to the other OBs during
configuration of the input/output modules.
After the OB has been started, the CPU updates the assigned process image partition for
inputs and reads in the process signals. At the end of the OB, the CPU writes the outputs of
the assigned process image partition directly to the peripheral outputs by the system without
having to wait for the completion of the cyclic program processing.As an alternative to methods already described, you can use the instruction "UPDAT_PI" or
the instruction "UPDAT_PO" at the start or the at the end of the respectively assigned OB to
update the process image. In STEP 7, these instructions are available on the "Instructions"
Task Card under "Extended instructions" and may be called from any point in the program.
Requirements for updating process image partitions with the "UPDAT_PI" and "UPDAT_PO"
instructions:
● The process image partitions cannot be assigned to any OB, i.e. they cannot be
automatically updatedPPI 0 (automatic update) cannot be updated with the "UPDAT_PI" and "UPDAT_PO"
instructions.With this instruction you read the sigWith this instruction you transmit the process image partition of the outputs to the output
modulesIn the isochronous mode interrupt OBs you use the instructions "SYNC_PI" and "SYNC_PO"
to update the process image partitions. Additional information on isochronous mode interrupt
OBs is available in the STEP 7 online help.You also have direct read and write access to the I/O, as an alternative to access via the
process image, should direct access be required for programming reasons. A direct (write)
I/O access also writes the process image. This prevents the situation where a subsequent
output of the process image overwrites the value written via direct access again.Additional information on process image partitions is available found in the function manual,
Cycle and response timesYou configure and assign parameters to the ET 200MP (interface module and I/O modules)
with STEP 7 or in the configuration software of another manufacturerYou can find an overview of the most important documents and links for the TIA Portal in the
following FAQ on the Internet The PROFIsafe address is saved permanently on the electronic coding element of the
/ET 200MP fail-safe modules. You can find additional information on the electronic
coding element in the section Replacing the coding element at the power connector of the
system power supply and load current supply (Page 285).
Note
The supply voltage L+ must be applied to the F-module during the assignment of the
PROFIsafe address (F-destination address together with F-source addressFor additional information on assigning the PROFIsafe address (F-destination address
together with the F-source address), refer to the SIMATIC Safety - Configuring and
ProgramminThe occurrence of a trigger results in the following reaction:
● If the event comes from an event source to which you have assigned an OB, this