Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5217N530 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5217N530: | TS5217N530 |
---|---|---|---|
Japan: | Japan | Color: | Black |
Temperature: | 20-90 | Material: | Iron |
Wire: | Wire | Dimension: | 60mm |
TS5217N530
these modules are not inserted in the configured order. | You use a control data record you have programmed to notify the CPU/interface module as |
Manufacturers of standard machines select a station option for a configuration level of the | to which modules are missing or located on different slots in a station option as compared to |
standard machine. They do not have change the project or download the modified configuration. |
the station master. The configuration control has no effect on the parameter assignment of |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
AU6550N2062
TS3664N1E1
TS3617N1E3
TS3641N1E1
TS5207N530
TS5208N569
TS4503N1022E100
TS3095N2
AU6649N2101
TS3664N1E2
TS3630N1214E3
TS3641N21E6
TS5208N510
TS5208N576
TS4503N1022E200
TS3103N156
FACODER
TS3664N2E3
TS5013N60
TS3641N22E7
TS5208N68
TS5210N450
TS4503N1202E200
TS3103N178
TS3664N2E4
TS5013N61
TS3641N2E3
TS5212N351
TS5210N453
TS4503N1205E200
TS3103N255
TS3664N50
TS5016N60
the modules.
The configuration control allows you to flexibly vary the centralized/distributed configuration.
As a precondition for this, the station option must be able to be derived from the station
masterWith configuration control (option handling), you handle various standard machine
configuration levels in one project without having to change the hardware configuration or
user program. Easy project handling and commissioning through use of a single STEP 7 project for all
station options.
● Easy handling during maintenance, versioning and upgrades.
● Hardware savings: Only the I/O modules needed for the current station option of the
machine are installed.
● Potential savings when building, commissioning and creating documentation for standard
machinesWith the , configuration control is possible both with centrally inserted modules and
with the ET 200MP distributed I/O system via PROFINET IO.
For automation system:
● STEP 7 Professional as of Version V13
● CPU S7-15XX as of firmware version V1.5
● The startup parameter "Comparison preset to actual configuration" is set to "Startup CPU
even if mismatch" (default setting).
You can find the "Comparison preset to actual configuration" parameter in the Inspector
window of the CPU properties under "General">"Startup".
For ET 200MP distributed I/O system:
● STEP 7 Professional as of Version V13
● IM 155-5 PN ST/HF
You have assigned the interface module to an IO controller/DP master in STEP 7
● The startup parameter "Comparison preset to actual module" is set to "Startup CPU even
if mismatch" (default setting).
You can find the "Comparison preset to actual module" parameter in the Inspector
window of the interface module properties in the "Startup" field under "General">"Module
parameters".Enable the "Allow to reconfigure the device via the user program" parameter when
configuring the CPU/interface module.
● For an CPU, you can find the "Allow to reconfigure the device via the user
program" parameter in the "Configuration control" area.
● For an IM 155-5 PN interface module, you can find the "Allow to reconfigure the device
via the user program" parameter in the "Configuration control" field under
"General">"Module parameters".To create a control data record for the configuration control, follow these steps:
1. Create a PLC data type that contains the structure of the control data record.
You can find the structure of the control data record:
– for the automation system in section Control data record for the
Automation System (Page 211).