Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5778N155 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5778N155: | TS5778N155 |
---|---|---|---|
Japan: | Japan | Color: | Black |
Temperature: | 30-90 | Dimension: | 80mm |
Material: | Iron | Wire: | Wire |
TS5778N155
fluid quantitiesThe technology modules SIWAREX WP521 and SIWAREX WP522 are used for the | The table below shows the main features of the technology modules for weighing |
acquisition and processing of signals from weighing or force transducers. You can connect | technology.RS 485 with Modbus RTU or for connecting the remote display (per channel) Ethernet interface with SIWATOOL protocol and Modbus TCP/IP (1 for both channels) |
one scale (WP521) or two separate scales (WP522) respectively to the modules. The SIWAREX modules offer high accuracy. |
ntegrated digital inputs DI 3x24VDC Integrated digital outputs DQ 4x24VDC |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3653N13E9
TS3103N40
TS3641N1E1
TS3641N2E3
TS3641N11E1
TS3641N12E3
TS3664N1E1
TS3664N1E2
TS3664N2E3
TS3664N2E4
TS3664N11E1
TS3664N11E2
TS3664N12E3
TS3664N12E4
TS3667N1E1
TS3667N1E2
TS3667N2E4
TS3667N1E3
TS3667N2E5
TS3667N2E6
TS3667N3E7
TS3667N3E8
TS3667N11E1
TS3667N11E2
TS3667N12E4
TS3667N11E3
TS3667N12E5
TS3667N12E6
TS3667N31E7
TS3667N13E8
TS3624N1E1
Load cell connection DMS load cells in 6- or 4-wire technology (per channel), 1 to 4 mV/V
Functions • Adjust the scale with weights or automatically
• 3 limits
• Tare
• Set to zero
• Trace
• Commission with SIWATOOL (service tool for PC)
Diagnostic interrupt ---
Hardware interrupt X (configurableThe weighing modules SIWAREX for SIMATIC - offer you the following advantages:
● Seamless integration of simple weighing applications such as platform and hopper scales
in SIMATIC -
● Use for level monitoring, e.g. silos and bunkers
● can be used centrally in SIMATIC - and in ET 200MP distributed I/O system
● SIWAREX WP521 ST for the setup of one scale
● SIWAREX WP522 ST for the setup of two separate scales, with the same space
requirements as WP521 ST
● free sample application on the Internet for the quick implementation of customer or
industry-specific solutionsThe power supply of an automation system to be dimensioned according to plant size. The
SIMATIC - CPUs are supplied via a load power supply. A system power supply that
supplies the backplane bus is integrated in the CPUs. Depending on the system
configuration, you can expand the integrated system power supply with up to two additional
system power supply modules. If your plant has high power requirements (e.g. I/O load
groups), you can connect additional load power supplies.
The main differences between the two power supplies for the SIMATIC - automation
system are listed below:Supplies the - system components such as CPU, system power supply (PS),
input/output circuits of the I/O modules and any sensors and actuators with 24 V DC.
You can install the load power supply directly to the left of the CPU (without connection to the backplane bus).
The supply of the CPU or of the interface module with 24 V DC is optional if you
supply the voltage for the backplane bus via a system power supply.
System power supply (PS) Supplies only internally required system voltage.
Supplies parts of the module electronics and the LEDs.The following figure shows a system configuration with load power supply and additional
system power supplyOverall configuration of power supply
In order to ensure the supply of the modules from the backplane bus, the incoming power is
compared with the required power in the TIA Portal engineering system or in the TIA
Selection Tool.
As early as in the planning stages, make sure that the power fed into the backplane bus is
always greater than or equivalent to the power drawnSystem power supplies supply the internal electronics of the - modules with power
via the backplane bus. The table below shows the available system power supply The load power supply modules with automatic range selection of the input voltage are
optimally adapted in design and functionality to the SIMATIC - controller. The table
below shows the available load power supply modules:● For higher output currents and 1-phase or 3-phase infeed
● With redundant installation of the 24 V power supply as protection against failure of a
power pack
● With buffering of the 24 V power supply (e. g. with DC UPS) as protection against power
failure
● With selective monitoring of 24 V loads against overload or short-circuitThe front connectors are used to wire the I/O modules. For modules with EMC-critical
signals, such as analog modules and technology modules, the front connectors also need a
shield contact.
The front connectors are available for 35 mm modules optionally with screw terminals and
push-in terminals and for 25 mm modules with push-in terminals. The front connectors for
25 mm modules are included in the scope of delivery of the I/O modules.
24 V DC is supplied, for example, via a plug-in infeed element for analog modules.
The shield contact consists of shield bracket and shield terminal. Together with the shield
terminal, the shield bracket allows the low-impedance, module-level connection of cable
shields with minimum installation times. The shielding takes place without tools.
The components (infeed element, shielding bracket and shield clamp) are included in the
scope of delivery of the modules.The individual modules are connected to one another with the U connector. The U connector
establishes the mechanical and electrical connection between the modules. The U
connectors are included in the scope of delivery of the I/O modules.Figure 3-24 Example: System cabling with SIMATIC TOP connect
For 35 mm modules, the system cabling SIMATIC TOP connect with prefabricated
connection elements is available in two versions:
● Fully modular connection consisting of front connector module, connection cables and