Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5308N616 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Temperature: | 20-90 | TS5308N616: | TS5308N616 |
Color: | Black | Wire: | Wire |
Dimension: | 80mm | Japan: | Japan |
TS5308N616
Information is provided below on the overall configuration of an S7-1500 automation system/ET 200MP distributed I/O |
|
system on a grounded infeed (TN-S system). The specific subjects discussed are: |
|
DIN VDE 0100) and IEC 60204 (c (corresponding to DIN VDE 0113) ● Load current supplies and load circuits |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3617N3E9
TS4514N2405E200
TS3617N1E2
TS2014N181E32
TS4603N7002E200
TS4602N6321E100
TS3617N2E4
TS3617N13E9
TS4515N1202E200
TS3617N11E1
TS2014N182E32
TS1505N55
TS4515N6000E200
TS4603N1000E100
TS3617N2E5
TS3617N40E3
TS4515N2405E200
TS3617N1E3
TS2014N185E32
TS4602N1000E200
TS4603N1000E200
TS3617N2E6
TS5214N566
TS5205N450
TS5213N551
TS5208N122
TS5208N23
TS5778N171
TS5210N53
TS5320N510
TS5000N632
TS5212N510
TS5213N510
TS5312N616
TS208N101
TS5208N130
TS5213N530
TS5013N68
TS5214N566
TS5200N500
TS5305N616
TS5669N220
TS5214N564
TS5246N158
TS5667N650
TS5213N551
TS5668N20
TS5667N120
TS5667N420
TS5246N160
TS5312N512
TS5208N122
TS5641N151
TS5270N15
TS5308N616
In the case of grounding incoming supplies (TN-S system) the neutral conductor (N) and theIn the case of grounding incoming supplies (TN-S system) the neutral conductor (N) and the
protective conductor (PE) are each grounded. Both conductors form a part of the overvoltage
concept. When a plant is in o Both conductors form a part of the overvoltage
concept. When a plant is in operation, the current flows across the neutral conductor. When
a fault occurs, for example a single ground fault between a live conducto fault between a live conductor and ground, the
current flows through the protective conductLoad current supplies/system power supplies with 24 V DC supply require safe electrical
separation. This protection is designated as SELV (Safety Extra Low Voltage)/PELV
(Protective Extra Low Voltage) in accordance with IEC 60364-4-41.
The wiring of SELV/PELV circuits must be separated from the wiring of other circuits that are
not SELV/PELV, or the insulation of all conductors must be rated for the higher voltageThe reference potential of the automation system/ ET 200MP distributed I/O system
is connected with the mounting rail through a high-resistance RC combination in the
CPU/interface module. In this way, high-frequency interference currents are conducted and
electrostatic charges are avoided. Despite the grounded mounting rail, the reference
potential of the automation system/ET 200MMP distributed I/O system has to be
considered as ungrounded due to the high-resistance connection.
IVarious measures as protection against short-circuits and overloads are required for setting
up a full installation. The nature of the components and the degree to which the required
measures are binding depeThe table refers to the following figure and compares the IEC (DIN VDE)
regulations.
Short-circuit and overload protection:
In groups for sensors and actuators
②
③
Single-pole protection of
circuits
• With grounded secondary circuit: fuse
unipolLoad current supply for AC load circuits Load current supply for AC load circuits
with more than five electromagnetic deviceThe figure below shows the overall configuration of the /ET 200MP (load current
supply and grounding concept) with infeed from a TN-S system.
Main switch
② Short-circuit and overload protection on the primary side
③ Short-circuit and overload protection on the secondary side