Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2014N181E32 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 30-90 |
Wire: | Wire | Dimension: | 70mm |
TS2014N181E32: | TS2014N181E32 | Japan: | Japan |
TS2014N181E32
DLETIME IN UInt The number of bit times required for idle line timeout. (Default value: 40). Only used with an idle line condition. |
These are the enabling bits for each character in start sequence |
0 to 65535 STARTCHAR IN Byte The start character used with the start character condition. (Default value: B#16#2) |
Disabling the bit associated with a character means any character will match, in this sequence position. |
STRSEQ1CTL IN Byte Sequence 1 ignore/compare control for each character: (Default value: B#16#0) |
STRSEQ1 IN Char[5] Sequence 1 start characters (5 characters). Default value: 0 |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3699N232
TS3738N1E7
TS3738N1E7
TS3741N3E8
TS374
TS3762N15E4
TS4126N1017E235
TS4127N1017E215
TS4127N1017E235
TS4231N6E17
TS4231N6E17
TS4244N10E24
TS4244N3E24
TS4502N1000E200
TS4502N1202E200
TS4502N2000E100
TS4503N1000E200
TS4503N1007E200
TS4503N1022E100
TS4503N1022E200
TS4503N1202E200
TS4503N1205E200
TS4503N1828E100
TS4503N2000E100
TS4503N2070E100
TS4503N2202E200
TS4503N2036E501
TS4506N1202E200
TS4507N1002E200
TS4507N1202E200
TS4507N1205E200
TS4507N1229E200
TS4507N2000E100
STRSEQ2CTL IN Byte Sequence 2 ignore/compare control for each character. Default
value: B#16#0)
STRSEQ2 IN Char[5] Sequence 2 start characters (5 characters). Default value: 0
STRSEQ3CTL IN Byte Sequence 3 ignore/compare control for each character. Default
value: B#16#0
STRSEQ3 IN Char[5] Sequence 3 start characters (5 characters). Default value: 0
STRSEQ4CTL IN Byte Sequence 4 ignore/compare control for each character. Default
value: B#16#0
STRSEQ4 IN Char[5] Sequence 4 start characters (5 characters), Default value: 0 Consider the following received hexadecimal coded message: "68 10 aa 68 bb 10 aa 16"
and the configured start sequences shown in the table below. Start sequences begin to be
evaluated when the first 68H character is successfully received. Upon successfully receiving
the fourth character (the second 68H), then start condition 1 is satisfied. Once the start
conditions are satisfied, the evaluation of the end conditions begins.
The start sequence processing can be terminated due to various parity, framing, or intercharacter
timing errors. These errors result in no received message, because the start
condition was not satisfied. The end of a message is determined by the specification of end conditions. The end of a
message is determined by the first occurrence of one or more configured end conditions.
The section "Message end conditions" in the topic "Configuring receive parameters
(Page 587)" describes the end conditions that you can configure in the RCV_CFG
instruction.
You can configure the end conditions in either the properties of the communication interface
in the device configuration, or from the RCV_CFG instruction. Whenever the CPU transitions
from STOP to RUN, the receive parameters (both start and end conditions) return to the
device configuration settings. If the STEP 7 user program executes RCV_CFG, then the
settings are changed to the RCV_CFG conditionsThis parameter specifies message end condition:
01H - Response time
02H - Message time
04H - Inter-character gap
08H - Maximum length
10H - N + LEN + M
20H - Sequence
MAXLEN IN UInt
1
Maximum message length: Only used when the
maximum length end condition is selected. 1 to 1024
bytes
N IN UInt
0
Byte position within the message of the length field. Only
used with the N + LEN + M end condition. 1 to 1022
bytes
LENGTHSIZE IN UInt
0
Size of the byte field (1, 2, or 4 bytes). Only used with the
N + LEN + M end condition.
LENGTHM IN UInt
0
Specify the number of characters following the length
field that are not included in the value of the length field.
This is only used with the N + LEN + M end condition. 0
to 255 bytes
RCVTIME IN UInt
200
Specify how long to wait for the first character to be
received. The receive operation will be terminated with an
error if a character is not successfully received within the
specified time. This is only used with the response time
condition. (0 to 65535 bit times with an 8 second
maximum)
This parameter is not a message end condition since
evaluation terminates when the first character of a
response is received. It is an end condition only in the
sense that it terminates a receiver operation because no
response is received when a response is expected. You
must select a separate end condition.
MSGTIME IN UInt
200
Specify how long to wait for the entire message to be
completely received once the first character has been
received. This parameter is only used when the message
timeout condition is selected. (0 to 65535 milliseconds)
CHARGAP IN UInt
12
Specify the number of bit times between characters. If the
number of bit times between characters exceeds the
specified value, then the end condition will be satisfied.
This is only used with the inter-character gap condition