Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5308N616 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5308N616: | TS5308N616 |
---|---|---|---|
Japan: | Japan | Temperature: | 40-120 |
Material: | Iron | Color: | Black |
Wire: | Wire | Dimension: | 49mm |
TS5308N616
Connect the temperature sensor | |
Use temperature sensors which comply with the Product Specifications published by | |
Philips Semiconductors |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3667N12E6
TS3667N31E7
TS3667N13E8
TS3624N1E1
TS3624N1E2
TS3624N2E3
TS3624N2E4
TS3624N3E5
TS3624N3E6
TS3630N1E1
TS3630N1E2
TS3630N2E3
TS3630N2E4
TS3630N3E5
TS3630N3E6
TS3630N1303E9
TS3630N1306
TS3630N11E1
TS3630N11E2
TS3630N12E3
TS3630N12E4
TS3630N13E5
TS3630N13E6
FA-CODER
TS5214N566
TS5205N450
TS5205N454
TS5205
N450
TS5205
N454
TS5205N452
TS5205
N452
TS5207
TS5208
TS5212
TS5213
TS5214
TS5231
TS5217
TS5233
TS5150
TS5300
TS5100
TS5000
TS5080
TS5170
TS5410
TS5200N500
TS5146
TS5270
TS5610
TS5620
TS1857
TS5607
TS5668N20
TS5667N120
TS5667N420
TS5645
TS5647
TS5648
TS5643
TS2223
TS2224
TS2225
TS20E12
TS13E11
TS5308N616
TS2650N11E78
TS5420N60
TS5208N131
TS3462N1E76
48-2500P8-L6-5VC/T-L3-12V
TS-5016N-60
TS5214N561
TS5214N510
TS2014N182E32
TS3653N2E5
TS5320N510
TS5016N-60
KTY83 series (KTY83/110)
● KTY84 series (KTY84/130)
Also take note of the accuracy of the temperature sensors.
The temperature is specified in 0.1 degrees C, 0.1 degrees K, and/or 0.1 degrees F, see
section Representation of the values for analog input channels (Page 262).
6ES7331-7KF02-0AB0
Properties
● 8 inputs in 4 channel groups
● Programmable measurement type at each channel group
– Voltage
– Current
– Resistance
– Temperature
● Programmable resolution at each channel group (9/12/14 bits + sign)
● Any measuring range selection per channel group
● Programmable diagnostics and diagnostic interrupt
● Programmable limit value monitoring for 2 channels
● Programmable hardware interrupt when limit is exceeded
● Electrically isolated to CPU and load voltage (not for 2-wire transducers)
Resolution
The resolution of measured values is directly dependent of the selected integration time. In
other words, the longer the integration time for an analog input channel, the higher the
resolution of a measured value.
Diagnostics
For information on diagnostics messages at the "group diagnostics" parameter, refer to
chapter Diagnostic messages of analog input modules.
Hardware interrupts
Hardware interrupts for channel groups 0 and 1 can be programmed in STEP 7. However,
set a hardware interrupt only for the first channel of a channel group, that is, either at
channel 0, or at channel 2
The diagrams below show various wiring options The input impedance depends on the
setting of the measuring range module, see table Measurement types and ranges.
• "Resistance measurement" is only available at one channel per group. The "2nd" channel
of the group is used accordingly for current measuring mode (IC). The "1st" channel of the
group returns the measured value. The "2nd" channel of the group is assigned the default
overflow value "7FFFH."
• There is no compensation of the line resistance with a 2 and 3-wire connection.
An interconnection of M- and MANA is prohibited when using grounded thermocouples. In
this case, you must ensure that low-resistance equipotential bonding is in place so that
the permitted common-mode voltage is not exceeded.
• Interconnect M- and MANA when using non-grounded thermocouples
Crosstalk between inputs > 50 dB
Operational limit (across entire temperature range, relative to the measurement range end value in the selected input
range)
• Voltage input 80 mV
250 mV to 1,000 mV
2.5 V to 10 V
± 1 %
± 0.6 %
± 0.8 %
• Current input 3.2 mA to 20 mA ± 0.7 %
• Resistance 150 Ω; 300Ω; 600 Ω ± 0. 7 %
• Thermocouple Types E, N, J, K, L ± 1. 1 %
• Resistance thermometer Pt 100/Ni 100 ± 0. 7 %
Pt 100 Klima ± 0. 8 %
Basic error limit (operational limit at 25 °C, relative to the measurement range end value in the selected input range)
• Voltage input 80 mV
250 mV to 1,000 mV
2.5 V to 10 V
± 0.7 %
± 0.4 %
± 0.6 %
Current input 3.2 mA to 20 mA ± 0.5 %
• Resistance 150 Ω; 300 Ω; 600 Ω ± 0.5 %
• Thermocouple Types E, N, J, K, L ± 0.7 %
• Resistance thermometer Pt 100/Ni 100 ± 0.5 %
Pt 100 Klima ± 0.6 %
Temperature error (relative to input range) ± 0.005%/K
Linearity error (relative to input range) ± 0.05 %
Repeat accuracy (in settled state at 25 °C, relative to input
range)
± 0.05 %
Temperature error of internal compensation ± 1 %
Maximum current at current input (destruction limit) 40 mA
Wiring of the signal transmitters using a 20-pin front connector
• for voltage measurement supported
• for current measurement
as 2-wire transducer
as 4-wire transducer
supported
supported
• For thermoresistor/resistance measurement
with 2-wire connection Supported, cable resistances are not compensated
with 3-wire connection Supported, cable resistances are not compensated
with 4-wire connection Supported, cable resistances are compensated
• Load of the 2-wire transducer max. 820 Ω
Characteristics linearization
• for thermocouples
programmable
Types E, N, J, K, L
• for resistance thermometers Pt 100 (Standard and Klima range)
Ni 100 (Standard and Klima range)
Temperature compensation
• Internal temperature compensation
programmable
supported
• External temperature compensation with compensating
box
supported
• Compensation for 0 °C reference junction temperature supported
• Technical unit of temperature measurement degrees Centigrade
Module SM 331; AI 8 x 12 Bit has measuring range modules
The measurement type and range is configured at the "measuring range" parameter in
STEP 7.
The default setting of the module is "voltage" measurement with "± 10V" range. You can use