Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2651N141E78 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS2651N141E78: | TS2651N141E78 |
---|---|---|---|
COLOR: | BLACK | Material: | Iron |
Temperature: | 40-120 | Dimension: | 50-130 |
TS2651N141E78
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS5210N458
TS4503N1828E100
TS3103N302
OAH14BSD
TS3667N1E2
TS5013N63
TS3641N32
TS5213N550
TS5210N530
TS4503N2000E100
TS3103N40
OAS66
TS3667N11E2
TS5016N61
TS3641N38
TS5213N551
TS5210N54
TS4503N2070E100
TS3132N32
OAS66
TS1857N16EP
TS3667N2E5
TS5016N63
TS3643N2
TS5308N510
TS20E12
TS4503N2202E200
TS3134N21
TS3667N2E6
TS5016N64
TS3643N212E5
TS530N33E9
TS2151N121E9
TS4503N2036E501
TS3134N22
OIS1000CT3L5V108
TS3667N3E7
TS5017N60
TS3643N233E8
TS5312-N250
TS2151N141E9
TS4506N1202E200
TS3134N317
OSE10243158
TS3667N3E8
TS5019N60
TS3653N11E2
TS5313N122
TS2228N33E1
TS4507N1002E200
TS3134N52
OSE5K-6-12-108
TS3667N13E8
TS5013N68
TS3653N12E5
TS5320N632
TS2640N141E172
TS4507N1202E200
OSE5KN-6-12-108
TS3674N37
TS5013N69
TS3653N13E8
TS5420
TS2640N181E100
TS4507N1205E200
TS3166N43
TS3679N2E1
TS5208N131
TS3653N1E1
TS5641N150
TS2640N321E64
TS4507N1229E200
TS3212N32
RFH102422
TS3679N3E1
TS5208N111E78
TS3617N47E4
TS1508N211
TS2650N11E78
TS4507N2000E100
TS3214N12
RFH1024-22-1M-68
TS3682N1
TS3617N1E1
TS3624N1E1
8 inputs in 4 channel groups | |
Programmable measurement type at each channel group – Temperature |
|
Programmable resolution at each channel group (15 bits + sign) |
Any measuring range selection per channel group
● Programmable diagnostics and diagnostic interrupt
● Programmable limit value monitoring for 8 channels
● Programmable hardware interrupt when limit is exceeded
● High-speed update of measured values at up to 4 channels
● Programmable hardware interrupt at end of cycle
● Electrically isolated from the CPU
● Supports parameter reassignment in RUN
Resolution
The resolution of measured values is independent of the selected integration time.
Diagnostics
For information on diagnostics messages at the "group diagnostics" parameter, refer to
chapter Diagnostic messages of analog input modules (Page 296).
Hardware interrupts
Hardware interrupts for channel groups 0 and 1 can be programmed in STEP 7. However,
set a hardware interrupt only for the first channel of a channel group, that is, either at
channel 0, or at channel 2
Terminal assignment
The diagrams below show various wiring options. These examples apply to all channels
(channel 0 to 7).
All 8 inputs are available as measurement channels if thermocouples are wired via reference
junctions which are regulated to 0 °C or 50 °C.
couple with external compensation
With this type of compensation, the temperature of the terminals at the reference junction is
established using a resistance thermometer Pt100 with a temperature range of -25 °C to
85 °C (see terminals 35 to 38).
Wire-break monitoring in 4-channel mode (hardware filter) at intervals of three seconds.
** In 8-channel software mode (software filter), series-mode rejection is reduced as follows:
• 50 Hz > 70 dB
• 60 Hz > 70 dB
• 400 Hz > 80 dB
*** The operational limit comprises only the basic error of the analog input at Ta = 25 °C and the total temperature error.
The total error must include the compensation error of the cold reference junction. Internal compensation of the reference
junction = max. 1.5 °C
External compensation of the reference junction = accuracy of the used external RTD ± 0.1 °C.
External compensation of the reference junction at which the reference junction is maintained at 0 °C or 50 °C = accuracy
of the temperature control of the reference junction.
**** Due to its small slope of approx. 0 °C to 40 °C, a lack of compensation for the reference junction temperature only has
a slight effect with thermocouple type B. With missing compensation and set measuring type "Compensation to 0 °C", the
deviation with thermocouple type B at measuring temperatures between:
• 700 °C and 1820 °C is < 0.5 °C
• 500 °C and 700 °C is < 0.7 °C.
If the reference junction temperature is approximately that of the module temperature, "internal compensation" should be
set. As a result, the error for the temperature range from 500 °C to 1820 °C is reduced to < 0.5 °C.
***** In 4-channel mode, the converted value settles to 100 % within 80 ms. The value determined in this process is set at
intervals of 3.3 ms (max. 10 ms).