Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5303N510 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5303N510: | TS5303N510 |
---|---|---|---|
Temperature: | 40-120 | Color: | Black |
Material: | Iron | Wire: | Wire |
Dimension: | 40-100 |
TS5303N510
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3641N38
TS3643N2
TS3643N212E5
TS3643N233E8
TS3653N11E2
TS3653N12E5
TS3653N13E8
TS3653N1E1
TS3653N1E2
TS3653N2E4
TS3653N2E5
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS3653N13E9
TS3653N44E8
TS3653N4E12
TS3653N14E12
TS3653N58E5
TS3653N65E27
TS3653N81E27
TS3653N78E5
TS3653N94E5
TS3653N181E8
TS3658N3
TS3664N1E1
TS3664N1E2
TS3664N2E3
TS3664N2E4
TS3664N50
TS3664N50
TS3667N1E2
TS3667N11E2
TS3667N2E5
TS3667N2E6
TS3667N3E7
TS3667N3E8
TS3667N13E8
TS3674N37
TS3679N2E1
TS3679N3E1
TS3682N1
TS3682N2
TS3684N11E3
TS3684N12E6
TS3684N13E8
TS3684N1E3
TS3684N2E6
TS3684N3E8
TS3692N103
TS3692N41
TS3692N42
TS3699N112
TS3699N172
TS3699N232
TS3738N1E7
TS3738N1E7
TS3741N3E8
TS374
TS3762N15E4
TS4126N1017E235
TS4127N1017E215
TS4127N1017E235
TS4231N6E17
TS4231N6E17
TS4244N10E24
TS4244N3E24
TS4502N1000E200
TS4502N1202E200
TS4502N2000E100
TS4503N1000E200
TS4503N1007E200
TS4503N1022E100
TS4503N1022E200
TS4503N1202E200
TS4503N1205E200
TS4503N1828E100
TS4503N2000E100
TS4503N2070E100
TS4503N2202E200
Because of the flexible structure of data record 2, you can use a separate external Pt100 | |
element for each channel. In addition, the channels can also be grouped together by means | |
of the user application in such a way that they all use the same external Pt100. This simply |
requires the same temperature value to be specified in DR2 for all the channels which use
the same reference temperature.
Note
Reference-junction compensation also results in an error in the temperature measured by
the isolated AI 6 x TC module. For this reason, great care must be taken when detecting the
reference junction. To keep this error to an absolute minimum, the reference-junction
temperature must remain as constant as possible.
0
This is just an example. The logic and memory allocation must be adapted to the structure of
the particular PLC program used.
The return value of SFC "WR_REC" (MW 22) can be evaluated in accordance with the
structure of the PLC program used. Additional information is available in the manual titled
System Software for /400 System and Standard Functions
Depending on the available comaptible function updates, the module AL 6 x TC can be
updated to the newest firmware version.
The most recent firmware versions are available from your representative or from
STEP 7 V 5.4 SP4 (HSP0158) or higher
● For central use of the module Al 6 x TC in a , the firmware update must occur in
the CPU-operating mode STOP. If the CPU is in the RUN operating mode, it may result in
unexpected behavior and the module will first be available again after a network
off/network on.
● If the module Al 6 x TC is set in a distributed IO device ET 200M, a firmware update is
also possible in the CPU-operating mode RUN.
This is how you update the firmware of a central or distributed module with the IM 153:
1. Select the module Al 6 x TC in HW Config.
. Select the "SPS" > "Update Firmware" menu command.
3. Use the "Browse" button to select the path to the firmware files (*.upd).
4. Click the "Execute" button.
– The module performs the firmware update.
For additional information, refer to the STEP 7 online help.
Note
• During the firmware update, the OB 83 (alarm due to removing and inserting modules),
the OB 85 (program execution error) and the OB 86 (error due to module rack failure) are
opened. If the diagnostics alarm of the module is approved, the OB 82 will also be
opened during the firmware update. Make sure that the OB is set correspondingly.
• If the red LED (SF) on the module blinks, an error occurred during the firmware update
and the update must be repeated. In this case, the bootloader version Ex.x.x is displayed
in the online diagnostics.
• A firmware update through HW-config is not permitted if the Al 6 x TC module is in
redundant mode.
Identification of the firmware
After the firmware update, you must label the firmware version on the module
I data: Information about the module, which is normally found on the module casing. I-data is
write-protected. They include:
● Hardware release status
● Firmware release status
● Serial number
M data: System-dependent information (e.g. plant designation).
M data is created during configuration.
All identification data (I&M-data) is retentively saved in a module and supports you with the
following tasks: