Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5246N160 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 30-100 |
WIRE: | WIRE | TS5246N160: | TS5246N160 |
Dimension: | 50mm |
TS5246N160
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
OIH60-8192P24-L6-5V
TS2651N141E78
TS5667N120
TS5667N420
TS5308N616
TS3462N1E76
TS2651N1E78
TS2651N131E78
TS2014N181E32
TS3103N40
TS3653N2E5
TS3653N3E8
TS3684N1E3
TS3684N2E6
TS3684N3E8
TS3667N3E8
TS3624N2E3
TS3624N2E4
TS3624N3E6
TS3630N1E1
TS3630N2E3
TS3630N1306
TS3630N1303E9
TS3630N1214E3
TS5013N60
TS5013N61
TS5016N60
TS5013N63
TS5013N64
TS5016N61
TS5013N66
TS5016N63
TS5016N64
TS5017N60
TS5019N60
TS5420N60
TS5778N155
TS5013N68
TS5013N69
TS5208N131
TS5208N23
TS2025N471E69TS2025N471E691E32
TS5208N111E78
TS5208N141E78
TS5631N224
PULSE
GENERATOR
RP-182
750PPR
PULSE
GENERATOR
RP-182
1500PPR
PULSE
GENERATORRP-482E,750PPR
ROTALY
ENCODER
RP-112A-T1,750PPR
ROTALY
ENCODER
RP-112A-T1,1500PPR
ROTALY
ENCODER
RP-112A-T1,3000PPR
ROTALY
ENCODER
RP-132,1500PPR
ROTALY
Functional earthing | Backplane bus interface |
Internal supply | Analog-to-Digital Converter |
Electrical isolation | Figure 6-46 Wiring and block diagram |
If you reassign parameters in RUN, the following special characteristic applies.
SF LED is lit:
If a diagnostics was pending prior to reconfiguration, the SF LEDs (on CPU, IM or module)
may be lit even though diagnostics is no longer pending and the module is operating
correctly.
Solution:
● Only assign new parameters if no diagnostics is pending, or
● unplug module and plug it in again.
You can configure the outputs for operation as voltage or current outputs, or disable them.
You program the outputs at the "output type" parameter in STEP 7.
The output type "Voltage" and output range "± 10 V" are set by default at the module. You
can always use this combination of output type and range without having to program the SM
332; AO 4 x 12 Bit in STEP 7.
For general information on programming analog modules, refer to the chapter Programming
analog modules (Page 294).
The table below provides overview of programmable parameters and of their defaults.
Table 6- 37 Overview of the parameters of SM 332; AO 4 x 12 Bit
The parameters can be set separately at each output channel of SM 332; AO 4 x 12 Bit. You
can assign separate parameters to each output channel.
Assign the parameters you set at the SFCs in the user program to the channel groups. Each
output channel of SM 332; AO 4 x 12 Bit is thus assigned to a channel group, i.e. output
channel 0 > channel group 0, for example.
Note
The output may carry incorrect interim values if you modify output ranges while SM 332; AO
4 x 12 Bit is in RUN.
To take unused output channels of SM 332; AO 4 x 12 Bit off power, set the "disabled"
argument at the "output type" parameter. Disabled channels do not have to be wired.
Line continuity check
SM 332; AO 4 x 12 Bit only performs a line continuity check at the current outputs.
In output ranges 0 mA to 20mA and ±20 mA, a "reliable" wire-break check is not possible for
output values of-20s to ±200 µA.
SM 332; AO 4 x 12 Bit only performs a short-circuit test at the voltage outputs.
Substitute values
You can configure the SM 332; AO 4 x 12 Bit for CPU STOP mode as follows: Outputs off
power, hold last value or set substitute values. The set substitute values must lie within the
output range
● 2 outputs in one group
● The outputs can be set separately as
– voltage output
– current output
● Resolution 12 bits
● Programmable diagnostics and diagnostic interrupt