Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2651N141E78 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 40-120 |
Wire: | Wire | TS2651N141E78: | TS2651N141E78 |
TS2651N141E78
Please contact with “Tommy” for the price
TS5205N452
TS5205
N452
TS5207
TS5208
TS5212
TS5213
TS5214
TS5231
TS5217
TS5233
TS5150
TS5300
TS5100
TS5000
TS5080
TS5170
TS5410
TS5200N500
TS5146
TS5270
TS5610
TS5620
TS1857
TS5607
TS5668N20
TS5667N120
TS5667N420
TS5645
TS5647
TS5648
TS5643
TS2223
TS2224
TS2225
TS20E12
TS13E11
TS5308N616
TS2650N11E78
TS5420N60
TS5208N131
TS3462N1E76
48-2500P8-L6-5VC/T-L3-12V
TS-5016N-60
TS5214N561
TS5214N510
TS2014N182E32
TS3653N2E5
TS5320N510
TS5016N-60
TS5016N60
TS5305N616
TS5008N12238
TS5214N564
TS5212N569
TS2651N111E78
TS2014N181E32
TS-5208N130
TS5207N76
TS5246N160
TS5312N616-2000C-T
TS5312N616
Transient recovery time | Common mode interference (Vpp < 1 V) |
with resistive load | Seriesmode interference (peak interference value < rated input |
with capacitive load | Crosstalk between inputs > 88 dB |
Operational limit (across entire temperature range, relative to the measurement range end value in the selected input
range)
• Voltage input 0 V to 10 V ± 0.7 %
• Resistance input 10 kΩ ± 3.5 %
• Temperature input Pt 100 ± 1 %
Basic error limit (operational limit at 25 °C, relative to the measurement range end value in the selected input range)
• Voltage input 0 V to 10 V ±0.5 %
• Resistance input 10 kΩ ± 2.8 %
• Temperature input Pt 100 ± 0.8 %
Temperature error (relative to input range) ± 0.01 %/K
Linearity error (relative to input range) ±0.05 %
Repeat accuracy (in settled state at 25 °C, relative to input range) ± 0.05 %
Interference frequency suppression, error limits of outputs
Crosstalk between outputs > 88 dB
Operational limit (across entire temperature range, relative to measurement range end value in the selected output range)
• Voltage output ± 1.0 %
Basic error limit (operational limit at 25 °C, relative to the measurement range end value in the selected output range)
• Voltage output ± 0.85 %
Temperature error (relative to output range) ± 0.01 %/K
Linearity error (relative to output range) ± 0.01 %
Repeat accuracy (in transient state at 25 °C, relative to output range) ± 0.01 %
Output ripple; range 0 Hz to 50 kHz (relative to output range) ± 0.1 %
Status, interrupts, diagnostics
Interrupts none
Diagnostic function none
Encoder selection data
Input ranges (rated values) / input impedance
• Voltage 0 V to 10 V 100 kΩ
• Resistance 10 kΩ 10 MΩ
• Temperature Pt 100 10 MΩ
Maximum voltage at voltage input (destruction limit) max. 20 V continuous; 75 V for max. duration of 1 s
(duty factor 1:20)
Wiring of the signal transmitters
• for voltage measurement
• for resistance measurement
with 2-wire connection
with 3-wire connection
with 4-wire connection
supported
supported
supported
supported
Characteristics linearization
• for resistance thermometers
programmable
Pt 100 (Climatic range)
Technical unit of data formats degrees Centigrade
Actuator selection data
Output range (rated value)
• Voltage 0 V to 10 V
Load impedance (in the rated output range)
• For voltage outputs
– capacitive load
min. 2.5 kΩ *
max. 1.0 µF
Voltage output
• Short-circuit protection
• Short-circuit current
Yes
max. 30 mA
Destruction limit against external voltages/currents
• Voltage at outputs to MANA max. 15 V, continuous
Wiring of the actuators
• for voltage output
2-wire connection
4-wire connection (measuring line)
using a 20-pin front connector
supported
not supported
* the error limits specified for the outputs are only valid when there is a high-ohm connection. In the entire load resistance
range, an additional error of <0.9 % can result.
For general information on programming analog modules, refer to the chapter Programming
analog modules (Page 294).
The table below provides an overview of configurable parameters, including defaults:
Table 6- 40 Summary of parameters SM 334; AI 4/AO 2 x 12 Bit
Measurement
• Measurement type disabled RTD-4L
V
R-4L
RTD-4L
Voltage
Resistance
(4-wire connection)
Thermal resistance
(linear, 4-wire connection)
dynamic Channel
• Measuring range 0 V to 10 V
10000 Ω
Pt 100 Klima
Pt 100 Klima
Output
• Output type
• Output range
disabled
Voltage
0 V to 10 V