Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5013N66 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5013N66: | TS5013N66 |
---|---|---|---|
Material: | Iron | Color: | Black |
Temperature: | 40-120 | Wire: | Wire |
Dimension: | 50mm |
TS5013N66
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
ENCODER
RP-132A-T1,750PPR
ROTALY
ENCODER
RP-873ZL,2048PPR
ROTALY
ENCODER
RP-886ZN,2500PPR
ROTALY
ENCODER
RP-5354D-CD-4096PPR
ROTALY
ENCODER
RP-132A-T1,600PPR
ROTALY
ENCODER
RP-132A,2000PPR
TS2025N471E69
TS2014N181E32
TS5208N111E78
TS5208N141E78
TS3684N1E3
TS3684N13E8
TS3617N1E3
TS3617N1E1
TS3617N1E2
TS3617N2E4
TS3630N11E1
TS3664N2E4
TS3653N13E7
TS3653N12E6
TS3653N2E5
TS3624N2E3
TS3653N13E9
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS1980N43E12
TS1980N56E12
TS1981N134E9
TS1981N53E19
TS1981N56E19
TS1981N56E19
TS1982N126E6
TS1982N128E6
TS1982N53E6
TS1982N56E18
TS1983N146E5
TS252N30E1
TS3503N11E43
TS3062E3
TS3092N11E12
TS3095N2
TS3103N156
TS3103N178
TS3103N255
TS3103N302
TS3103N40
TS3132N32
TS3134N21
The measuring principle of all thermocouples is the same, irrespective of their type. |
Enable • Diagnostics interrupt • Process interrupt when limit exceeded |
Any measuring range per channel group | Fast Mode (can only be set if the |
Programmable diagnostics and diagnostic interrupt | operation in the DP slave |
properties)
yes/no no static Module
Process interrupt trigger
• High limit
• Low limit
May be restricted by the measuring range.
from 32511 to - 32512
from - 32512 to 32511
- dynamic Channel
Diagnostics
• Group diagnostics yes/no no static Channel
group
Measurement
• Measurement type disabled
Voltage V
4DMU current (4-wire transducer)
2DMU current (2-wire transducer)
V
dynamic Channel or
channel
group • Measuring range See the table Measurement types and
ranges
± 10 V
• Noise suppression none; 400 Hz; 60 Hz; 50 Hz 50 Hz
Reproducible reaction times (i.e. of the same length) are achieved in a SIMATIC system by
means of a constant DP bus cycle, and synchronization of the single cyclic processes
outlined below:
● Independent user program cycle. The length of the cycle time may vary due to non-cyclic
program branching.
● Independent and variable DP cycle on the PROFIBUS subnet
● Cyclic operation of the backplane bus of the DP slave.
● Cyclic signal preparation and conversion at the electronic modules of the DP slave.
The constant DP cycle runs in synchronism and at the same length. The CPU run levels
(OB61 to OB64) and isochronous IO are synchronized with this cycle. I/O data are therefore
transferred at defined and constant intervals (isochronous mode.)
Requirements
● The DP master and slave must support isochronous mode. You require STEP 7 V5.2 or
higher.
Mode of operation: Isochronous mode
Table 6- 16 Conditions of isochronous mode:
Standard Mode
Filtering and processing time TWE between reading actual values and writing these to the
transfer buffer(the value defined for TWE applies, irrespective of the enable status of diagnostics)
max. 625 μs
including an input delay time of 10 µs
TDPmin 3.5 ms
Diagnostics interrupt max. 4 x TDP
Fast Mode (only possible with 6ES7331-7HF01-0AB0)
Filter and processing time TWE between reading actual value and writing the results to the
transfer buffer (diagnosis not selectable)
max. 625 μs
including an input delay time of 10 µs
TDPmin 1 ms
Note
You can accelerate the cycle of your DP system by setting "Fast Mode." However, this is at
the expense of diagnostics: Diagnostics functions will be disabled in this operating mode.