Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5016N63 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5016N63: | TS5016N63 |
---|---|---|---|
Japan: | Japan | COLOR: | BLACK |
Temperature: | 40-120 | Material: | Iron |
TS5016N63
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3503N11E43
TS3062E3
TS3092N11E12
TS3095N2
TS3103N156
TS3103N178
TS3103N255
TS3103N302
TS3103N40
TS3132N32
TS3134N21
TS3134N22
TS3134N317
TS3134N52
TS3166
TS3166N43
TS3212N32
TS3214N12
TS3214N13
TS3214N15
TS3214N16
TS3214N44
TS3218
TS3218N42
TS3218N5
TS3250E12
TS3275N125
TS3153N15E18
TS3602N213E8
TS3602N233E8
TS3602N31E8
TS3617N1E1
TS3617N1E2
TS3617N11E1
TS3617N1E3
TS3617N2E4
TS3617N2E5
TS3617N2E6
TS3617N2E7
TS3617N3E10
TS3617N3E8
TS3617N13E8
TS3617N376
TS3617N381
TS3617N3E9
TS3617N13E9
TS3617N40E3
TS3617N47E4
TS3624N1E1
TS3624N21E1
TS3624N21E2
TS3624N1E2
TS3624N102E4
TS3624N103E5
TS3624N203E5
TS3624N22E4
TS3624N23E5
TS3624N2E3
TS3624N2E4
TS3624N3E5
TS3624N3E6
TS3630N1303E9
TS3630N1309E5
TS3630N1306
TS3630N1E1
TS3630N1E2
TS3630N2E3
TS3630N2E4
TS3630N3E5
TS3630N101E2
TS3630N102E4
TS3630N22E3
A wire break can only be signaled by means of the lit SF LED and the diagnostic bytes must be evaluated in the user program if diagnostic interrupts are disabled. |
|
Under the following circumstances, wire-break detection can take up to 2 s | |
If a wire break occurs during voltage measurement. |
If a wire break occurs on the front-connector jumpers from shunt (250 Ω) to the inputs
during current measurement.
The measured value can go through the entire valid value range during the wire break
detection.
When there are configured measuring ranges ± 10 V, ± 5 V, 1 to 5 V or 4 to 20 mA, the wire
break test is not activated and a diagnostic interrupt is enabled, the module triggers a
diagnostic interrupt when the underflow is reached. The module detect the underflow when
the input signal is below 0.296 V or 1.185 mA.
Overflow, underflow and hardware interrupt limits
The limits in diagnostics response to overflow and underflow in certain measuring ranges
differ compared to the listed ranges starting at the chapterAnalog value representation for
analog input channels of the manual. In certain situations the numerical methods of the
module software used to evaluate the process variables do not return values up to 32511.
Do not set any hardware interrupt limits higher than the lowest possible overflow or
underflow response limits. End of cycle interrupt starting at the chapter Analog value
representation for analog input channels. You can synchronize a process with the conversion cycle of the module by enabling the end
of cycle interrupt. The interrupt is set when enabled channels have been converted.
The table below shows the contents of the 4 bytes of additional OB40 information during
process or end of cycle interrupts.Operation of SM 331; AI 8 x 16 Bit on ET 200M requires one of the following IM 153 x:
● IM 153-1; as of 6ES7153-1AA03-0XB0, E 01
● IM 153-2; as of 6ES7153-2AA02-0XB0; E 05
● IM 153-2; as of 6ES7153-2AB01-0XB0; E 04
Programming restrictions when operating SM 331; AI 8 x 16 Bit on Certain parameters are not supported when operating an electrically isolated SM 331; AI 8
16 Bit analog input module on an ET200M PROFIBUS slave system in combination with a
PROFIBUS master which is not an S7 master. Non-S7 masters do not support hardware
interrupts. All parameters associated with these functions are disabled for this reason. This
includes hardware interrupt enable, hardware restrictions and end the enabling of cycle
interrupts. All other parameters are allowed.
8 inputs in 4 channel groups
● Measurement type programmable for each channel group:
– Voltage
– Current
● Programmable resolution for each group (13 bits + sign)
● Any measuring range per channel group
● Programmable diagnostics and diagnostic interrupt
● Programmable limit value monitoring for 2 channels
● Programmable hardware interrupt when limit is exceeded
● High-speed update of measured values
● Supports isochronous mode
● Electrical isolation from the CPU