Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2651N131E78 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 20-90 |
Dimension: | 80mm | Wire: | Wire |
TS2651N131E78: | TS2651N131E78 |
TS2651N131E78
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
GENERATORRP-482E,750PPR
ROTALY
ENCODER
RP-112A-T1,750PPR
ROTALY
ENCODER
RP-112A-T1,1500PPR
ROTALY
ENCODER
RP-112A-T1,3000PPR
ROTALY
ENCODER
RP-132,1500PPR
ROTALY
ENCODER
RP-446Z,750PPR
ROTALY
ENCODER
M-52004
RP872ZL
2048PPR
ROTALY
ENCODER
RP-132A-T1,750PPR
ROTALY
ENCODER
RP-873ZL,2048PPR
ROTALY
ENCODER
RP-886ZN,2500PPR
ROTALY
ENCODER
To send data over an established connection, execute TSEND_C with a rising edge on REQ. After a successful send operation, TSEND_C sets the DONE parameter for one cycle |
To establish a connection, execute TRCV_C with parameter CONT = 1 |
To establish a connection and send data, execute TSEND_C with CONT =1 and REQ = 1. After a successful send operation, TSEND_C sets the DONE parameter for one cycle. TRCV_C operations |
To receive data, execute TRCV_C with parameter EN_R = 1. TRCV_C receives the data continuously when parameters EN_R = 1 and CONT = 1. |
The following functions describe the operation of the TRCV_C instruction: | To terminate the connection, execute TRCV_C with parameter CONT = 0. The connection will be aborted immediately, and data could be lost. |
TRCV_C handles the same receive modes as the TRCV instruction. The following table
shows how data is entered in the receive area.
Table 10- 4 Entering the data into the receive area
Protocol
variant
Entering the data in the
receive area
Parameter
"connection_type"
Value of the LEN parameter Value of the RCVD_LEN
parameter (bytes)
TCP Ad hoc mode B#16#11 65535 1 to 1472
TCP Data reception with
specified length
B#16#11 0 (recommended) or 1 to
8192, except 65535
1 to 8192
ISO on TCP Ad hoc mode B#16#12 65535 1 to 1472
ISO on TCP Protocol-controlled B#16#12 0 (recommended) or 1 to
8192, except 65535
1 to 8192 The "ad hoc mode" exists with the TCP and ISO on TCP protocol variants. You set "ad hoc
mode" by assigning "65535" to the LEN parameter. The receive area is identical to the area
formed by DATA. The length of the received data will be output to the parameter
RCVD_LEN.
If you store the data in an "optimized" DB (symbolic only), you can receive data only in
arrays of Byte, Char, USInt, and SInt data types.
Note
Importing of S7-300/400 STEP 7 projects containing "ad hoc mode" into the
In S7-300/400 STEP 7 projects, "ad hoc mode" is selected by assigning "0" to the LEN
parameter. In the , you set "ad hoc mode" by assigning "65535" to the LEN
parameter.
If you import an S7-300/400 STEP 7 project containing "ad hoc mode" into the , you
must change the LEN parameter to "65535".
Note
Due to the asynchronous processing of TSEND_C, you must keep the data in the sender
area consistent until the DONE parameter or the ERROR parameter assumes the value
TRUE.
For TSEND_C, a TRUE state at the parameter DONE means that the data was sent
successfully. It does not mean that the connection partner CPU actually read the receive
buffer.
Due to the asynchronous processing of TRCV_C, the data in the receiver area are only
consistent when parameter DONE = 1.
Table 10- 5 TSEND_C and TRCV_C instructions BUSY, DONE, and ERROR parameters
BUSY DONE ERROR Description
TRUE irrelevant irrelevant The job is being processed.
FALSE TRUE FALSE The job is successfully completed.
FALSE FALSE TRUE The job was ended with an error. The cause of the error can be found
in the STATUS parameter.
FALSE FALSE FALSE A new job was not assigned.Job executed without error
0 7000 No job processing active
0 7001 Start job processing, establishing connection, waiting for connection partner
0 7002 Data being sent or received
0 7003 Connection being terminated
0 7004 Connection established and monitored, no job processing active
1 8085 LEN parameter is greater than the largest permitted value.
1 8086 The CONNECT parameter is outside the permitted range.
1 8087 Maximum number of connections reached; no additional connection possible.
1 8088 LEN parameter is not valid for the memory area specified in DATA.
1 8089 The CONNECT parameter does not point to a data block.
1 8091 Maximum nesting depth exceeded.
1 809A The CONNECT parameter points to a field that does not match the length of the
connection description.
1 809B The local_device_id in the connection description does not match the CPU.
1 80A1 Communications error:
The specified connection was not yet established
The specified connection is currently being terminated; transmission over this
connection is not possible
The interface is being reinitialized
1 80A3 Attempt being made to terminate a nonexistent connection
1 80A4 IP address of the remote partner connection is invalid. For example, the remote partner
IP address is the same as the local partner IP address.
1 80A5 Connection ID is already in use.
1 80A7 Communications error: You called TDISCON before TSEND_C was complete.
1 80B2 The CONNECT parameter points to a data block that was generated with the keyword
UNLINKED.
1 80B3 Inconsistent parameters:
Error in the connection description