Home ProductsTAMAGAWA

TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78

TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78

    • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78
    • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78
    • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78
    • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78
    • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78
  • TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78

    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS2651N131E78

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    TAMAGAWA: TAMAGAWA Material: Iron
    Color: Black Temperature: 20-90
    Dimension: 80mm Wire: Wire
    TS2651N131E78: TS2651N131E78

    TS2651N131E78

     TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78TAMAGAWA TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78 TS2651N131E78

    Guang Zhou Lai Jie Electric Co.,LTD

    Please contact with “Tommy” for the price

    GENERATORRP-482E,750PPR

    ROTALY

    ENCODER

    RP-112A-T1,750PPR

    ROTALY

    ENCODER

    RP-112A-T1,1500PPR

    ROTALY

    ENCODER

    RP-112A-T1,3000PPR

    ROTALY

    ENCODER

    RP-132,1500PPR

    ROTALY

    ENCODER

    RP-446Z,750PPR

    ROTALY

    ENCODER

    M-52004

    RP872ZL

    2048PPR

    ROTALY

    ENCODER

    RP-132A-T1,750PPR

    ROTALY

    ENCODER

    RP-873ZL,2048PPR

    ROTALY

    ENCODER

    RP-886ZN,2500PPR

    ROTALY

    ENCODER

     

     

    To send data over an established connection, execute TSEND_C with a rising edge on
    REQ. After a successful send operation, TSEND_C sets the DONE parameter for one
    cycle
    To establish a connection, execute TRCV_C with parameter CONT = 1
    To establish a connection and send data, execute TSEND_C with CONT =1 and REQ =
    1. After a successful send operation, TSEND_C sets the DONE parameter for one cycle.
    TRCV_C operations
    To receive data, execute TRCV_C with parameter EN_R = 1. TRCV_C receives the data
    continuously when parameters EN_R = 1 and CONT = 1.
    The following functions describe the operation of the TRCV_C instruction: To terminate the connection, execute TRCV_C with parameter CONT = 0. The
    connection will be aborted immediately, and data could be lost.

    TRCV_C handles the same receive modes as the TRCV instruction. The following table
    shows how data is entered in the receive area.
    Table 10- 4 Entering the data into the receive area
    Protocol
    variant
    Entering the data in the
    receive area
    Parameter
    "connection_type"
    Value of the LEN parameter Value of the RCVD_LEN
    parameter (bytes)
    TCP Ad hoc mode B#16#11 65535 1 to 1472
    TCP Data reception with
    specified length
    B#16#11 0 (recommended) or 1 to
    8192, except 65535
    1 to 8192
    ISO on TCP Ad hoc mode B#16#12 65535 1 to 1472
    ISO on TCP Protocol-controlled B#16#12 0 (recommended) or 1 to
    8192, except 65535
    1 to 8192 The "ad hoc mode" exists with the TCP and ISO on TCP protocol variants. You set "ad hoc
    mode" by assigning "65535" to the LEN parameter. The receive area is identical to the area
    formed by DATA. The length of the received data will be output to the parameter
    RCVD_LEN.
    If you store the data in an "optimized" DB (symbolic only), you can receive data only in
    arrays of Byte, Char, USInt, and SInt data types.
    Note
    Importing of S7-300/400 STEP 7 projects containing "ad hoc mode" into the
    In S7-300/400 STEP 7 projects, "ad hoc mode" is selected by assigning "0" to the LEN
    parameter. In the , you set "ad hoc mode" by assigning "65535" to the LEN
    parameter.
    If you import an S7-300/400 STEP 7 project containing "ad hoc mode" into the , you
    must change the LEN parameter to "65535".
    Note
    Due to the asynchronous processing of TSEND_C, you must keep the data in the sender
    area consistent until the DONE parameter or the ERROR parameter assumes the value
    TRUE.
    For TSEND_C, a TRUE state at the parameter DONE means that the data was sent
    successfully. It does not mean that the connection partner CPU actually read the receive
    buffer.
    Due to the asynchronous processing of TRCV_C, the data in the receiver area are only
    consistent when parameter DONE = 1.
    Table 10- 5 TSEND_C and TRCV_C instructions BUSY, DONE, and ERROR parameters
    BUSY DONE ERROR Description
    TRUE irrelevant irrelevant The job is being processed.
    FALSE TRUE FALSE The job is successfully completed.
    FALSE FALSE TRUE The job was ended with an error. The cause of the error can be found
    in the STATUS parameter.
    FALSE FALSE FALSE A new job was not assigned.Job executed without error
    0 7000 No job processing active
    0 7001 Start job processing, establishing connection, waiting for connection partner
    0 7002 Data being sent or received
    0 7003 Connection being terminated
    0 7004 Connection established and monitored, no job processing active
    1 8085 LEN parameter is greater than the largest permitted value.
    1 8086 The CONNECT parameter is outside the permitted range.
    1 8087 Maximum number of connections reached; no additional connection possible.
    1 8088 LEN parameter is not valid for the memory area specified in DATA.
    1 8089 The CONNECT parameter does not point to a data block.
    1 8091 Maximum nesting depth exceeded.
    1 809A The CONNECT parameter points to a field that does not match the length of the
    connection description.
    1 809B The local_device_id in the connection description does not match the CPU.
    1 80A1 Communications error:
     The specified connection was not yet established
     The specified connection is currently being terminated; transmission over this
    connection is not possible
     The interface is being reinitialized
    1 80A3 Attempt being made to terminate a nonexistent connection
    1 80A4 IP address of the remote partner connection is invalid. For example, the remote partner
    IP address is the same as the local partner IP address.
    1 80A5 Connection ID is already in use.
    1 80A7 Communications error: You called TDISCON before TSEND_C was complete.
    1 80B2 The CONNECT parameter points to a data block that was generated with the keyword
    UNLINKED.
    1 80B3 Inconsistent parameters:
     Error in the connection description