Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5214N566 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Dimension: | 60mm |
Temperature: | 70mm | TS5214N566: | TS5214N566 |
Wire: | Wire | Japan: | Japan |
IN_OUT TCON_Param Pointer to the connection description 0: Job is not yet started or still running. | ERROR OUT Bool Status parameters with the following values: 0: No error |
1: Job completed without error. BUSY OUT Bool 0: Job is completed. |
1: Error occurred during processing. STATUS provides detailed information on the type of error. |
1: Job is not yet completed. A new job cannot be triggered. |
STATUS OUT Word Status information including error information. (Refer to the Error and Status condition codes in the table below.) |
TS5214N566
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3653N13E9
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS1980N43E12
TS1980N56E12
TS1981N134E9
TS1981N53E19
TS1981N56E19
TS1981N56E19
TS1982N126E6
TS1982N128E6
TS1982N53E6
TS1982N56E18
TS1983N146E5
TS252N30E1
TS3503N11E43
TS3062E3
TS3092N11E12
TS3095N2
TS3103N156
TS3103N178
TS3103N255
TS3103N302
TS3103N40
TS3132N32
TS3134N21
TCON instruction to set up and establish the
communication connection. You use parameters to specify the active and passive
communication end point partners. After the connection is set up and established, it is
automatically maintained and monitored by the CPU.
If the connection is terminated due to a line break or due to the remote communications
partner, for example, the active partner attempts to re-establish the configured connection.
You do not have to execute TCON again.
An existing connection is terminated and the set-up connection is removed when the
TDISCON instruction is executed or when the CPU has gone into STOP mode. To set up
and re-establish the connection, you must execute TCON again.
Table 10- 10 ERROR and STATUS condition codes for TCON and TDISCON
ERROR STATUS Description
0 0000 Connection was established successfully.
0 7000 No job processing active
0 7001 Start job processing; establishing connection (TCON) or terminating connection
(TDISCON)
0 7002 Follow-on call (REQ irrelevant); establishing connection (TCON) or terminating
connection (TDISCON)
1 8086 The ID parameter is outside the permitted address range.
1 8087 TCON: Maximum number of connections reached; no additional connection possible.
1 809B TCON: The local_device_id in the connection description does not match the CPU.
1 80A1 TCON: Connection or port is already occupied by user.
1 80A2 TCON: Local or remote port is occupied by the system.
1 80A3 Attempt being made to re-establish an existing connection (TCON) or terminate a nonexistent
connection (TDISCON).
1 80A4 TCON: IP address of the remote connection end point is invalid; it may match the local
IP address.
1 80A5 TCON: Connection ID is already in use.
1
()
80A7 TCON: Communications error: you executed TDISCON before TCON was complete.
TDISCON must first completely terminate the connection referenced by the ID. TCON: When using the ISO on TCP (connection_type = B#16#12) to establish a
passive connection, condition code 80B4 alerts you that the TSAP entered did not
conform to one of the following address requirements:
For a local TSAP length of 2 and a TSAP ID value of either E0 or E1 (hexadecimal)
for the first byte, the second byte must be either 00 or 01.
For a local TSAP length of 3 or greater and a TSAP ID value of either E0 or E1
(hexadecimal) for the first byte, the second byte must be either 00 or 01 and all
other bytes must be valid ASCII characters.
For a local TSAP length of 3 or greater and the first byte of the TSAP ID does not
have a value of either E0 or E1 (hexadecimal), then all bytes of the TSAP ID must
be valid ASCII characters.
Valid ASCII characters are byte values from 20 to 7E (hexadecimal).
1 80B6 TCON: Parameter assignment error in parameter connection_type
1 80B7 TCON: Data type and/or length of the transmitted data does not fit in the area in the
partner CPU, in which it is to be written.
1) 80B8 TCON: Parameter in the local connection description and Parameter ID are different.
1 80C3 TCON: All connection resources are in use.
1 80C4 Temporary communications error:
The connection cannot be established at this time (TCON).
The configured connection is currently being removed by TDISCON (TCON).
The connection is currently being established (TDISCON).
The interface is receiving new parameters (TCON and TDISCO