Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2651N111E78 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Material: | Iron | TAMAGAWA: | TAMAGAWA |
---|---|---|---|
TS2651N111E78: | TS2651N111E78 | Color: | Black |
Temperature: | 20-90 | Japan: | Japan |
Wire: | Wire | Dimension: | 49mm |
TS2651N111E78
You can make required changes in your AS-i slave device and CPU I/O addresses. | It is detected by the master as a new slave without an address assignment and is not included in normal communication until assigned an address. |
The green "CM" LED is ON. In the "Set AS-i address" field, you can change the AS-i slave address. A new slave that has | Configuration error |
not been assigned an address always has address 0. | When the yellow "CER" LED is ON, |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3667N11E1
TS3667N11E2
TS3667N12E4
TS3667N11E3
TS3667N12E5
TS3667N12E6
TS3667N31E7
TS3667N13E8
TS3624N1E1
TS3624N1E2
TS3624N2E3
TS3624N2E4
TS3624N3E5
TS3624N3E6
TS3630N1E1
TS3630N1E2
TS3630N2E3
TS3630N2E4
TS3630N3E5
TS3630N3E6
TS3630N1303E9
TS3630N1306
TS3630N11E1
TS3630N11E2
TS3630N12E3
TS3630N12E4
TS3630N13E5
TS3630N13E6
FA-CODER
TS5214N566
TS5205N450
TS5205N454
TS5205
N450
TS5205
N454
there is an error in the AS-i slave device configuration.
Select the "ACTUAL > EXPECTED" button to overwrite the AS-i master CM1243-2 module
slave device configuration with the AS-i field network slave device configuration.
10.5 S7 communication
10.5.1 GET and PUT instructions
You can use the GET and PUT instructions to communicate with S7 CPUs through
PROFINET and PROFIBUS connections:
● Accessing data in a remote CPU: An CPU can only use absolute addresses in
the ADDR_x input field to address variables of remote CPUs (S7-200/300/400/1200).
● Accessing data in a standard DB: An CPU can only use absolute addresses in
the ADDR_x input field to address DB variables in a standard DB of a remote S7 CPU.
● Accessing data in an optimized DB: An CPU cannot access DB variables in an
optimized DB of a remote CPU.
● Accessing data in a local CPU: An CPU can use either absolute or symbolic
addresses as inputs to the RD_x or SD_x input fields of the GET or PUT instruction,
respectively. Use the GET instruction to read data from
a remote S7 CPU. The remote CPU can
be in either RUN or STOP mode.
STEP 7 automatically creates the DB
when you insert the instruction. Use the PUT instruction to write data to a
remote S7 CPU. The remote CPU can be
in either RUN or STOP mode.
STEP 7 automatically creates the DB
when you insert the instruction. escription
ERROR
STATUS
Output
Output
Bool
Word
? ERROR=0
STATUS value:
– 0000H: neither warning nor error
– <> 0000H: Warning, STATUS supplies detailed information
? ERROR=1
There is an error. STATUS supplies detailed information about
the nature of the error.
ADDR_1 InOut Remote
ADDR_2 InOut Remote
ADDR_3 InOut Remote
ADDR_4 InOut Remote
Pointer to the memory areas in the remote CPU that stores the
data to be read (GET) or that is sent (PUT).
RD_1 (GET)
SD_1 (PUT)
InOut Variant
RD_2 (GET)
SD_2 (PUT)
InOut Variant
RD_3 (GET)
SD_3 (PUT)
InOut Variant
RD_4 (GET)
SD_4 (PUT)
InOut Variant