Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5017N60 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Japan: | Japan |
Temperature: | 20-90 | Wire: | Wire |
TS5017N60: | TS5017N60 | Dimension: | 70mm |
TS5017N60,
Interface type Type of interface | Note: The user can specify the remote address of a third party device for an "unspecified" communication partner. |
Subnet name Name assigned to the subnets | Connection ID ID number: Automatically generated by the GET/PUT connection parameter assignment |
Address Assigned IP addresses | Connection name Local and Partner CPU data storage location: Automatically generated by the GET/PUT connection parameter assignment |
Guang Zhou Lai Jie Electric Co.,LTDConnection name Local and Partner CPU data storage location: Automatically generated by the
GET/PUT connection parameter assignment
Please contact with “Tommy” for the price
TS2650N11E78
TS3762N15E4
TS1981N56E19
TS3653N3E9
TS5850N70
TS3630N1306
TS5013N69
TS2650N101E78
TS4126N1017E235
TS1981N56E19
TS3653N13E9
TS5N2E18
TS3630N1E1
TS5013N61
TS2651N111E78
TS4127N1017E215
TS1982N126E6
TS3653N44E8
TS3630N1E2
TS5013N89
TS2651N181E78
TS4127N1017E235
TS1982N128E6
8001231S
TS3653N4E12
TS5013N64
TS3630N2E3
TS5016N
TS5000N532
TS4231N6E17
TS1982N53E6
800123-2R
TS3653N14E12
TS5420N60
TS3630N2E4
TS5016N60
TS5000N632
Active connection
establishment
Checkbox to select Local CPU as the active connection
Connection
parameter:
General
One-way Checkbox to specify a one-way or two-way connection; read-only
Note: In a PROFINET GET/PUT connection, both the local and partner
devices can act as a server or a client. This allows a two-way connection, and
the "One-way" checkbox is unchecked.
In a PROFIBUS GET/PUT connection, in some cases, the Partner device can
only act as a server (for example, an S7-300), and the "One-way" checkbox is
checked.There are three ways to change the system-defined connection IDs:
1. The user can change the current ID directly on the GET/PUT block. If the new ID belongs
to an already existing connection, the connection is changed.
2. The user can change the current ID directly on the GET/PUT block, but the new ID does
not already exist. A new S7 connection is created by the system.
3. The user can change the current ID through the "Connection overview" dialog: The userinput
is synchronized with the ID-parameter on the corresponding GET/PUT block.
Note
The parameter "ID" of the GET/PUT block is not a connection name, but a numerical
expression which is written like the following example: W#16#1 The connection name is editable through a special user control, the "Connection overview"
dialog. This dialog offers all the available S7 connections which could be selected as an
alternative for the current GET/PUT communication. The user can create a completely new
connection in this table. Click the button to the right of the "Connection name" field to start
the "Connection overview" dialog. For the GET or PUT instruction, the "Properties" tab is automatically displayed in the
inspector window with the following menu selections:
● "Configuration"
● "Connection parameters"