Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5013N68 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
TS5013N68: | TS5013N68 | Japan: | Japan |
Color: | Black | Temperature: | 30-90 |
Dimension: | 70mm | Wire: | Wire |
TS5013N68
No special characters such as umlauts, brackets, underscore, slash, blank space, etc. The only special character permitted is the dash. |
You can also create an ARRAY "nos" that is shorter then 240 bytes, |
The station name must not begin or end with the "-" character. ● The station name must not begin with a number. |
but not less than 2 bytes. In this case, you must adjust the "len" (length of subfield) tag accordingly.In the following example, in the "addr" subfield, the "InterfaceAddress" (IP address), |
The station name form n.n.n.n (n = 0, ... 999) is not permitted. ● The station name must not begin with the string "port-xyz" or "port-x |
"SubnetMask", and "DefaultRouter" (IP router) are changed. In the CPU "Properties", "Ethernet address" page, |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS5013N68
the "Set IP address using a different method" radio button must be
clicked to enable you to change the IP address using the "T_CONFIG" instruction after the
program is downloaded.
Table 10- 27 How to change IP parameters In the following example, both the "addr" and "nos" (Name of station) subfields are changed.
In the CPU "Properties", "Ethernet address" page, the "Set PROFINET device name using a
different method" radio button must be clicked to enable you to change the PROFINET
device name using the "T_CONFIG" instruction after the program is downloaded.
Table 10- 28 How to change IP parameters and PROFINET IO device names Many of the Open User Communication instructions use the REQ input to initiate the
operation on a low to high transition. The REQ input must be high (TRUE) for one execution
of an instruction, but the REQ input can remain TRUE for as long as desired. The instruction
does not initiate another operation until it has been executed with the REQ input FALSE so
that the instruction can reset the history state of the REQ input. This is required so that the
instruction can detect the low to high transition to initiate the next operation.
When you place one of these instructions in your program, STEP 7 prompts you to identify
the instance DB. Use a unique DB for each instruction call. This ensures that each
instruction properly handles inputs such as REQ. This is a reference to the "Local ID (hex)" on the "Network view" of "Devices and networks"
in STEP 7 and is the ID of the network that you want to use for this communication block.
The ID must be identical to the associated parameter ID in the local connection description.
DONE, NDR, ERROR, and STATUS output parameters
These instructions provide outputs describing the completion statusIs set TRUE for one execution to indicate that the last request
completed without errors; otherwise, FALSE.
NDR Bool FALSE Is set TRUE for one execution to indicate that the requested action
has completed without error and new data has been received;
otherwise, FALSE.
BUSY Bool FALSE Is set TRUE when active to indicate that:
The job is not yet complete.
A new job cannot be triggered.
Is set FALSE when job is complete.
ERROR Bool FALSE Is set TRUE for one execution to indicate that the last request
completed with errors, with the applicable error code in STATUS;
otherwise, FALSE.
STATUS Word 0 Result status:
If the DONE or NDR bit is set, then STATUS is set to 0 or to an
informational code.
If the ERROR bit is set, then STATUS is set to an error code.
If none of the above bits are set, then the instruction returns
status results that describe the current state of the function.
STATUS retains its value for the duration of the execution of the
function.
Note
Note that DONE, NDR, and ERROR are set for one execution only.