Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5016N60 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 20-80 |
TS5016N60: | TS5016N60 | Japan: | Japan |
Wire: | Wire |
TS5016N60
LEN produces an output of the amount in bytes of AINFO data that is returned. | Refer to the AINFO parameters and TINFO parameters of the online information system of STEP 7 for information on how to interpret the TINFO and AINFO data |
AINFO and TINFO are updated with interrupt-related information.If you assign a destination area for TINFO or AINFO that is too short, RALRM cannot return | contains error information that is interpreted as ARRAY[1...4] OF BYTE, with the following structure: B#16#00, if no error |
the full information.MLEN can limit the amount of AINFO data that is returned. |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS2151N1E45
TS3699N232
TS3653N3E9
2000144
TS3653N2E4
TS5778N155
TS3624N2E4
TS4559N3E15
TS2151N11E45
TS3738N1E7
TS1980N43E12
482048P6L65V
TS3653N2E5
TS5778N157
TS3624N3E5
TS4886N9079E411
TS2640N321E64
TS3738N1E7
TS1980N56E12
60798024
TS3653N2E6
TS5787N10
TS3624N3E6
TS-5008-N-65
TS2641N31E64
TS3741N3E8
TS1981N134E9
610568-1A
TS3653N3E7
TS5850N60
TS3630N1303E9
Function ID from DPV1-PDU: If an error occurs, B#16#80 is OR'ed (for read
data record: B#16#DE; for write data record: B#16#DF). If no DPV1 protocol
element is used, then B#16#C0 will be output.
STATUS[2] Error_Decode Location of the error ID
STATUS[3] Error_Code_1 Error ID
STATUS[4] Error_Code_2 Manufacturer-specific error ID expansionNo error, no warning
70 00 Reserved, reject Initial call; no active data record transfer
01 Reserved, reject Initial call; data record transfer has started Intermediate call; data record transfer already active
90 Reserved, pass Invalid logical start address
92 Reserved, pass Illegal type for Variant pointer
93 Reserved, pass The DP component addressed via ID or F_ID is not
configured.
96 The "RALRM (Page 278)" cannot supply the OB start
information, management information, header
information, or additional interrupt information.
For OBs 4x, 55, 56, 57, 82, and 83, you can use the
"DPNRM_DG (Page 286)" instruction to read the current
diagnostics message frame of the relevant DP slave
asynchronously (address information from OB start
information).
A0 Read error Negative acknowledgement while reading from the
module
A1 Write error Negative acknowledgement while writing to the module
A2 Module failure DP protocol error at layer 2 (for example, slave failure or
bus problems)
A3 Reserved, pass PROFIBUS DP: DP protocol error with Direct-DataLink-Mapper
or User-Interface/User
PROFINET IO: General CM error
A4 Reserved, pass Communication on the communication bus disrupted
A5 Reserved, pass -
A7 Reserved, pass DP slave or modules is occupied (temporary error).
A8 Version conflict DP slave or module reports non-compatible versions.
A9 Feature not supported Feature not supported by DP slave or module
AA to AF User specific DP slave or module reports a manufacturer-specific error
in its application. Please check the documentation from
the manufacturer of the DP slave or module.
B0 Invalid index Data record not known in module; illegal data record
number ≥ 256
B1 Write length error The length information in the RECORD parameter is
incorrect.
With "RALRM": Length error in AINFO
Note: Refer to the online information system of
STEP 7 for immediate access to information on how
to interpret the "AINFO" returned buffers.
With "RDREC (Page 275)" and "WRREC
(Page 275)": Length error in "MLEN"
B2 Invalid slot The configured slot is not occupied.
B3 Type conflict Actual module type does not match specified module
type.
B4 Invalid area DP slave or module reports access to an invalid area.
B5 Status conflict DP slave or module not ready
80
B6 Access denied DP slave or module denies accessB7 Invalid range DP slave or module reports an invalid range for a
parameter or value.
B8 Invalid parameter DP slave or module reports an invalid parameter.
B9 Invalid type DP slave or module reports an invalid type:
With "RDREC (Page 275)": Buffer too small (subsets
cannot be read)
With "WRREC (Page 275)": Buffer too small (subsets
cannot be written)
BA to BF User specific DP slave or module reports a manufacturer-specific error
when accessing. Please check the documentation from
the manufacturer of the DP slave or module.
C0 Read constraint conflict With "WRREC (Page 275)": The data can only be
written when the CPU is in STOP mode.
Note: This means that data cannot be written by the
user program. You can only write the data online with
a PG/PC.
With "RDREC (Page 275)": The module routes the
data record, but either no data is present or the data
can only be read when the CPU is in STOP mode.
Note: If data can only be read when the CPU is in
STOP mode, no evaluation by the user program is
possible. In this case, you can only read the data
online with a PG/PC.
C1 Write constraint conflict The data of the previous write request to the module for
the same data record has not yet been processed by the
module.
C2 Resource busy The module is currently processing the maximum
possible number of jobs for a CPU.
C3 Resource unavailable The required operating resources are currently occupied.
C4 Internal temporary error. Job could not be carried out.
Repeat the job. If this error occurs often, check your
installation for sources of electrical interference.
C5 DP slave or module not available
C6 Data record transfer was cancelled due to priority class
cancellation.
C7 Job aborted due to warm or cold restart on the DP
master.
C8 to CF DP slave or module reports a manufacturer-specific
resource error. Please check the documentation from the
manufacturer of the DP slave or module.
Dx User specific DP Slave specific. Refer to the description of the DP
Slave.
00 to FF Error in the initial call parameter (with "RALRM
(Page 278)": MODE)
81
00 Illegal operating mode
82 00 to FF Error in the second call parameter 00 to FF Error in the eighth call parameter (with "RALRM
(Page 278)": TINFO)
Note: Refer to the online information system of STEP 7
for immediate access to information on how to interpret
the "TINFO" returned buffers.
01 Wrong syntax ID
23 Quantity structure exceeded or destination area too small
24 Wrong range ID
32 DB/DI number out of user range
88
3A DB/DI number is NULL for area ID DB/DI, or specified
DB/DI does not exist.
00 to FF Error in the ninth call parameter (with "RALRM
(Page 278)": AINFO)
Note: Refer to the online information system of STEP 7
for immediate access to information on how to interpret
the "AINFO" returned buffers.
01 Wrong syntax ID
23 Quantity structure exceeded or destination area too small
24 Wrong range ID
32 DB/DI number out of user range
89
3A DB/DI number is NULL for area ID DB/DI, or specified
DB/DI does not exist.
8A 00 to FF Error in the 10th call parameter
8F 00 to FF Error in the 15th call parameter
FE, FF 00 to FF Profile-specific error
Array element STATUS[4]