Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5208N130 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | TS5208N130: | TS5208N130 |
---|---|---|---|
Japan: | Japan | Material: | Iron |
Color: | Black | Temperature: | 40-80 |
Dimension: | 70mm | Wire: | Wire |
TS5208N130
You have not entered the start address in the LADDR parameter in hexadecimal format. | write (DPWR_DAT) consistent data exists at the logical address specified in LADDR. |
8092 A type other than Byte is specified in the Any reference. | 80A0 Access error detected while the I/O devices were being accessed (DPRD_DAT). |
8093 No DP module/PROFINET IO device from which you can read (DPRD_DAT) or to which you can | 80A1 Access error detected while the I/O devices were being accessed (DPWR_DAT). |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS5000N632
TS4231N6E17
TS1982N56E18
TS3653N58E5
TS5778N155
TS3630N3E5
TS5003N632
TS4244N10E24
TS1982N56E18
800123-R-F
TS3653N65E27
TS5208N23
TS3630N101E2
TS5017N56
TS5005N122
TS4244N3E24
TS1983N146E5
TS3653N81E27
TS2025N471E69
TS3630N102E4
TS5017N60
TS5007N122
TS4502N1000E200
TS1983N146E5
TS3653N78E5
TS2014N181E32
TS3630N22E3
TS5108-N153-5V
TS5007N635
TS4502N1202E200
TS252N30E1
80B0 Slave failure on external DP interface module
80B1 The length of the specified destination (DPRD_DAT) or source (DPWR_DAT) area is not identical to
the user data length configured with STEP 7 Basic.
80B2, 80B3, 80C2,
80Fx
System error with external DP interface module (DPRD_DAT) and (DPWR_DAT)
87xy, 808x System error with external DP interface module (DPRD_DAT)
85xy System error with external DP interface module (DPWR_DAT)
80C0 The data have not yet been read by the module (DPRD_DAT).
80C1 The data of the previous write job on the module have not yet been processed by the module
(DPWR_DAT).
8xyy1 General error information
Extended instructions
8.3 Distributed I/O (PROFINET, PROFIBRefer to "Extended instructions, Distributed I/O: Error information for RDREC, WRREC, and
RALRM" (Page 280) for more information on general error codes.
Note
If you access DPV1 slaves, error information from these slaves can be forwarded from the
DP master to the instruction. You can use the DPNRM_DG (Read diagnostic data) instruction with PROFIBUS. Use the DPNRM_DG instruction to read the current diagnostic data of
a DP slave in the format specified by EN 50 170 Volume 2,
PROFIBUS. The data that has been read is entered in the destination
area indicated by RECORD following error-free data transfer. REQ=1: Read request
LADDR IN HW_DPSLAVE Configured diagnostic address of the DP slave: Must be the address of
the station and not for the I/O device. Select the station (and not the
image of the device) in the "Network" view of the "Device configuration"
to determine the diagnostic address.
Enter the addresses in hexadecimal format. For example, diagnostic
address 1022 means LADDR:=W#16#3FE.
RET_VAL OUT Int If an error occurs while the function is active, the return value contains
an error code. If no error occurs, the length of the data actually
transferred is entered in RET_VAL.
RECORD OUT Variant Destination area for the diagnostic data that were read. Only the Byte
data type is permitted. The minimum length of the data record to be
read or the destination area is 6. The maximum length of the data
record to be sent is 240.
Standard slaves can provide more than 240 bytes of diagnostic data up
to a maximum of 244 bytes. In this case, the first 240 bytes are
transferred to the destination area, and the overflow bit is set in the
data.
BUSY OUT Bool BUSY=1: The read job is not yet completed
You start the read job by assigning 1 to the input parameter REQ in the DPNRM_DG
instruction call. The read job is executed asynchronously, in other words, it requires several
DPNRM_DG instruction calls. The status of the job is indicated by the output parameters
RET_VAL and BUSY. No error -
7000 First call with REQ=0: No data transfer active; BUSY has the value 0. -
7001 First call with REQ =1: No data transfer active; BUSY has the value 1. Distributed I/Os
7002 Interim call (REQ irrelevant): Data transfer already active; BUSY has the
value 1.
Distributed I/Os
8090 Specified logical base address invalid: There is no base address. -
8092 The type specified in the Any reference is not Byte. -
8093 This instruction is not permitted for the module specified by LADDR
(S7-DP modules for S7-1200 are permitted).
LADDR specifies the I/O device instead of specifying the station. Select
the station (and not the image of the device) in the "Network" view of