Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5205N454 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Japan: | Japan |
---|---|---|---|
Material: | Iron | TS5205N454: | TS5205N454 |
Color: | Black | Dimension: | 40mm |
Temperature: | 30-90 | Wire: | Wire |
TS5205N454
If the CYCLE time = 0, then the interrupt event is deactivated and the interrupt OB is not executed. |
If lower and higher priority OBs are called in the same time interval, |
The PHASE (phase shift) time is a specified delay time that occurs before the CYCLE time interval begins. |
the lower priority OB is only called after the higher priority OB has finished processing. |
You can use the phase shift to control the execution timing of lower priority OBs. |
The execution start time for the low priority OB can shift depending on the processing time of higher priority OBs. |
Please contact with “Tommy” for the price
TS3641N2E3
TS5212N351
TS5210N453
TS4503N1205E200
TS3103N255
TS3664N50
TS5016N60
TS3641N12E3
TS5212N510
TS5210N458
TS4503N1828E100
TS3103N302
OAH14BSD
TS3667N1E2
TS5013N63
TS3641N32
TS5213N550
TS5210N530
TS4503N2000E100
TS3103N40
OAS66
TS3667N11E2
TS5016N61
TS3641N38
TS5213N551
TS5210N54
TS4503N2070E100
TS3132N32
OAS66
TS1857N16EP
TS3667N2E5
TS5016N63
TS3643N2
TS5308N510
581
W WW W
W WW W
2%
+LJKHUSULRULW
2%
ORZSULRULW
2%FDOOZLWKRXWSKDVHVKLIW
If yoGet parameter and execution status from a cyclic
interrupt OB. The values that are returned existed
at the time QRY_CINT was executed. OB number (accepts symbolic name like OB_MyOBName)
RET_VAL OUT Int Execution condition code
CYCLE OUT UDInt Time interval, in microseconds
PHASE OUT UDInt Phase shift, in microseconds
STATUS OUT Word Cyclic interrupt status code:
Bits 0 to 4, see the STATUS table below
Other bits, always 0 During CPU RUN
1 During startup
1 0 The interrupt is enabled.
1 Interrupt is disabled via the DIS_IRT instruction.
2 0 The interrupt is not active or has elapsed.
1 The interrupt is active.
4 0 The OB identified by OB_NR does not exist.
1 The OB identified by OB_NR exists.If an error occurs, RET_VAL displays the appropriate error code and the parameter STATUS
= 0. You can start and cancel time delay interrupt processing with the SRT_DINT and CAN_DINT
instructions, or query the interrupt status with the QRY_DINT instruction. Each time delay
interrupt is a one-time event that occurs after the specified delay time. If the time delay event
is cancelled before the time delay expires, the program interrupt does not occur. SRT_DINT starts a time delay interrupt that
executes an OB when the delay time specified by
parameter DTIME has elapsed.
ret_val := CAN_DINT(
ob_nr:=_int_in_);
CAN_DINT cancels a time delay interrupt that has
already started. The time delay interrupt OB is not
executed in this case.
ret_val := QRY_DINT(
ob_nr:=_int_in_,
status=>_word_out_);
QRY_DINT queries the status of the time delay
interrupt specified by the OB_NR parameter.
Table 8- 96 Data types for the parameters
Parameter and type Data type Description
OB_NR IN OB_DELAY Organization block (OB) to be started after a time-delay: Select from
the available time-delay interrupt OBs that were created using the "Add
new block" project tree feature. Double-click on the parameter field,
then click on the helper icon to see the available OBs.
DTIME 1 IN Time Time delay value (1 to 60000 ms) SIGN 1 IN Word Not used by the S7-1200: Any value is accepted. A value must be
assigned to prevent errors.
RET_VAL OUT Int Execution condition code
STATUS OUT Word QRY_DINT instruction: Status of the specified time-delay interrupt OB,
see the table below The SRT_DINT instruction specifies a time delay, starts the internal time delay timer, and