    Product Details:

    Place of Origin: Japan
    Brand Name: Tamagawa
    Certification: CE
    Model Number: TS5208N130

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Packaging Details: carton
    Delivery Time: in stock
    Payment Terms: T/T, Western Union, MoneyGram
    Supply Ability: 100pcs/week
    Contact Now
    Detailed Product Description
    Tamagawa: Tamagawa TS5208N130: TS5208N130
    Japan: Japan Material: Iron
    Color: Black Temperature: 30-120
    Dimension: 40mm Wire: Wire

    TS5208N130

     

    Guang Zhou Lai Jie Electric Co.,LTD

    Please contact with “Tommy” for the price

    TS5246N164

    TS2650N1E78

    TS2650N11E78

    TS2650N101E78

    TS5212N500

    TS5308N616

    TS5314N616

    TS2640N671E110

    TS2605N1E64

    TS2640N71E10

    TS4503N2000E100

    TS4503N2000E200

    TS5205N456

    TS5205N450

    TS5205N454

    TS1981N56E19

    TS1981N56E18

    TS2651N111E78

    TS2651N181E78

    TS2640N321E64

    TS5214N566/N8566

    TS5208N8566

    TS5667N120

    TS5667N420

    TS2651N181E78

    TS2651N141E78

    TS6026N151

    TA8481N0300

    TA8480N0100

    TA8480N0200

    TS5000N632

    TS2014N181E32

    TS2651N131E78

    TS5667N420

    TS5303N510

    TS5246N574

    TS5208N143

    TS4603N1680E200

    TS4603N1680E200

    TA8480N0000

    TS5216N579AU6802N1

    TS5213N510TAMAGAWA

    TS3624N22E3

    TS5238N352

    OIH48-2000P8-L6-5V

    TS5212N530

    TS5214N8566

    TS5214N8566

    TS5246N160

    TS2620N21E11

    TS2650N11E78

    TS4602N1033E200

    TS5668N41

    TS5314N510-2500C/T

    35-2000P4-L6-5V

    TS5668N43

    48-5000p8-L6-5V

    TS5217N577

    TS3641N

    4509N1021E100

    OIH48-2500P8-L6-5V60

    TS2651N141E78

    TS3653N2E5

    TS5246N160

    TS5246N473

     

     

     

     

     

    OIH60-8192P24-L6-5V

    TS2651N141E78

    TS5667N120

    TS5667N420

    TS5308N616

    TS3462N1E76

    TS2651N1E78

    TS2651N131E78

    TS2014N181E32

    TS3103N40

    TS3653N2E5

    TS3653N3E8

    TS3684N1E3

    TS3684N2E6

    TS3684N3E8

     

     

    TAMAGAWA TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130TAMAGAWA TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130TAMAGAWA TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130TAMAGAWA TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130 TS5208N130

    The channel conversion time is based on the programmed noise suppression 50 Hz. The channel conversion time is 65 ms when you set an interference frequency of
    60 Hz.
    The channel
    conversion time is 76 ms,
    You can reduce channel conversion times to 16 ms by setting an interference
    frequency of 400 Hz
    including communication time, at a set interference frequency of When you set 50, 60 and 400 Hz , the channel conversion time
    amounts to 88 ms.

    The module then has to switch to a different channel of the group bymeans of the OptoMOS relay. Opto-MOS relays require 7 ms for switching and settling. The
    following table shows this relationship.Table 6- 12 Cycle times in 8-channel modeThe converted value settles to 100% within 80 ms and is updated every 10 ms when 4-channel mode isset. The channel and module cycle times are always identical, because themodule does not change between the channels of a group: 10 ms.Channel conversion time = channel cycle time = module cycle time = 10 ms
    Set the "disabled" value at the "measuring method" parameter for unused channels. Thissetting reduces module cycle times.
    As certain programmed inputs may remain unused due to the channel group configuration in
    8-channel mode, make allowances for the special features of these inputs outlined below to
    activate the diagnostics functions at the channels being used:● Measuring range 1 V to 5 V: wire the used input and unused input of the same channel
    group in parallel.

    Current measurement, 4 to 20 mA: Connect unused input in series to the input of the
    same channel group. A shunt resistor must be connected for each programmed and
    unused channel.
    ● Other measuring ranges: Short-circuit the plus and minus inputs of the channel.
    Line continuity check
    The wire break test is available for the voltage measuring range 1 to 5 V and the current
    measuring range 4 to 20 mA.
    When there is a configured measuring range of 1 to 5 V or 4 to 20 mA and the wire break
    test is activated, the analog input module reports a wire break in the diagnostics when
    underflow (-32768) is reached.
    ● The module also triggers a diagnostic interrupt if this function is enabled in the program.
    ● A wire break can only be signaled by means of the lit SF LED and the diagnostic bytes
    must be evaluated in the user program if diagnostic interrupts are disabled.
    Under the following circumstances, wire-break detection can take up to 2 s: