Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | TS2650N1E78 |
Model Number: | TS2650N1E78 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
TAMAGAWA: | TAMAGAWA | COLOR: | BLACK |
---|---|---|---|
Temperature: | 30-120 | Dimension: | 40mm |
Wire: | Wire | TS2650N1E78: | TS2650N1E78 |
Japan: | Japan |
TS2650N1E78
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3218
TS3218N42
TS3218N5
TS3250E12
TS3275N125
TS3153N15E18
TS3602N213E8
TS3602N233E8
TS3602N31E8
TS3617N1E1
TS3617N1E2
TS3617N11E1
TS3617N1E3
TS3617N2E4
TS3617N2E5
TS3617N2E6
TS3617N2E7
TS3617N3E10
TS3617N3E8
TS3617N13E8
TS3617N376
TS3617N381
TS3617N3E9
TS3617N13E9
TS3617N40E3
TS3617N47E4
TS3624N1E1
TS3624N21E1
TS3624N21E2
TS3624N1E2
TS3624N102E4
TS3624N103E5
TS3624N203E5
TS3624N22E4
TS3624N23E5
TS3624N2E3
TS3624N2E4
TS3624N3E5
TS3624N3E6
TS3630N1303E9
TS3630N1309E5
TS3630N1306
TS3630N1E1
TS3630N1E2
TS3630N2E3
TS3630N2E4
TS3630N3E5
TS3630N101E2
TS3630N102E4
TS3630N22E3
TS3630N22E4
TS3631N1E1
TS3636N6
TS3641N1E1
TS3641N21E6
TS3641N22E7
TS3641N2E3
TS3641N12E3
TS3641N32
TS3641N38
TS3643N2
TS3643N212E5
TS3643N233E8
TS3653N11E2
TS3653N12E5
TS3653N13E8
TS3653N1E1
TS3653N1E2
TS3653N2E4
TS3653N2E5
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS3653N13E9
TS3653N44E8
TS3653N4E12
TS3653N14E12
TS3653N58E5
TS3653N65E27
TS3653N81E27
TS3653N78E5
Interference frequency suppression at interference frequency f1 in Hz |
|
Basic execution time of the module in ms (all channels | |
enabled)Interference frequency suppression at F = n |
frequencyCommon mode interference (VCM < 2.5 V)
• Seriesmode interference (peak interference value < rated
input range)
> 70 dB
> 40 dB
Crosstalk between Operational limit (across entire temperature range, relative to the measurement range end value in the selected input
range)Interrupts
• Limit interrupt
• Diagnostic interrupt
programmable
Channels 0 and 2
programmable
Diagnostic functions
• Group error display
• Reading diagnostics information
programmable
red LED (SF)
supported
Encoder selection data
Input ranges (rated values) / input impedanceMaximum current at current input (destruction limit) 40 mA
Wiring of the signal transmitters using a 20-pin front connector
• for voltage measurement supported
• for current measurement
as 2-wire transducer
as 4-wire transducer
supported
supported
• For thermoresistor/resistance measurement
with 2-wire connection Supported, cable resistances are not compensated
with 3-wire connection Supported, cable resistances are not compensated
with 4-wire connection Supported, cable resistances are compensated
• Load of the 2-wire transducer max. 820 Ω
Characteristics linearization
• for thermocouples
programmable
Types E, N, J, K, L
• for resistance thermometers Pt 100 (Standard and Klima range)
Ni 100 (Standard and Klima range)
Temperature compensation
• Internal temperature compensation
programmable
supported
• External temperature compensation with compensating
box
supported
• Compensation for 0 °C reference junction temperature supported
• Technical unit of temperature measurement degrees Centigrade
Module SM 331; AI 8 x 12 Bit has measuring range modules
The measurement type and range is configured at the "measuring range" parameter in
STEP 7.
The default setting of the module is "voltage" measurement with "± 10V" range. You can use
these default settings without having to program the SM 331; AI 8 x 12 Bit in STEP 7.
Measuring range modulesYou may have to change the position of the measuring range modules to suit themeasurement type and range (see the chapter Setting the measuring types and ranges ofanalog input channels). The necessary settings are also available on the module's imprint.Mark theposition of the measuring range module on the front door (see figure)ThermocoupleTC-I
(internal comparison) (thermal voltagemeasurement)Linearization is ignoredType N [NiCrSi-NiSi]Type E [NiCr-CuNi]Type J [Fe-CuNi]Type K [NiCr-Ni]Type L [Fe-CuNi]AThermocoupleTC-E(external comparison) (thermovoltage
measurement)Linearization is ignoredThermocouple(linear, internal comparison)(temperature measurement) TC-ILType N [NiCrSi-NiSi]Type E [NiCr-CuNi]Type J [Fe-CuNi]Type K [NiCr-Ni]Type L [Fe-CuNi]A
Thermocouple(linear, external comparison)
(temperature measurement) TC-ELCurrent (2-wire transducer)
2DMU
4 mA to 20 mA DCurrent (4-wire transducer)4DMU 3.2 mA± 10 mA0 mA to 20 mA mA to 20 mA± 20 mACResistance (4-wire connection)R-4L150 Ω300Ω600ΩAThermoresistor(linear, 4-wire connection)(temperaturemeasurement)RTD-4LPt 100KlimaNi100 KlimaPt 100 StandardNi 100 StandardThe channels of SM 331; AI 8 x 12 Bit arearrangedin four groups of two channels. You caassign parameters only to onechannel group.SM 331; AI 8 x 12 Bit is equipped with one measuring range module per channelgroup.The table below shows the relevant configuration of channel groups. The channelgroupumber is required to program SFC parameters in the user programTable 6- 19 Assignment of SM 331; AI 8x12 bit channels to channel groups