Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS5016N60 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
Tamagawa: | Tamagawa | TS5016N60: | TS5016N60 |
---|---|---|---|
Japan: | Japan | Material: | Iron |
Color: | Black | Temperature: | 30-120 |
Dimension: | 49mm |
TS2640N321E64
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS3643N2
TS3643N212E5
TS3643N233E8
TS3653N11E2
TS3653N12E5
TS3653N13E8
TS3653N1E1
TS3653N1E2
TS3653N2E4
TS3653N2E5
TS3653N2E6
TS3653N3E7
TS3653N3E8
TS3653N3E9
TS3653N13E9
TS3653N44E8
TS3653N4E12
TS3653N14E12
TS3653N58E5
TS3653N65E27
TS3653N81E27
TS3653N78E5
TS3653N94E5
TS3653N181E8
TS3658N3
TS3664N1E1
TS3664N1E2
TS3664N2E3
TS3664N2E4
TS3664N50
TS3664N50
TS3667N1E2
TS3667N11E2
TS3667N2E5
TS3667N2E6
TS3667N3E7
TS3667N3E8
Short-circuit to L | 3.29 Digital output module SM 322; DO 8 x DC 24 V/ 0.5 A; with diagnostics interrupt; (6ES7322-8BF00-0AB0) |
static Channel | Module data Manual, 06/2017, A5E00105505-AJ 179 |
Set substitute value "1" yes/no no dynamic Channel Digital modules |
3.29.2 SM 322; DO 8 x DC 24 V/0.5 A - Diagnostics |
Special considerations must be given if you use the Configuration in RUN function.
SF LED is lit:Status before re-configuration diagnostics on, SF LEDs lit among others (on CPU, IM ormodule), although diagnostics are no longer pending and the module is operating correctly.Solution:● Only change the configuration when no diagnostics are pending for the module or● Pulling and plugging the module.The general procedure of programming digital modules is described in the chapterProgramming digital modules (Page 58).SM 322; DO 8 x DC 24 V/0.5 A - ParametersThe table below lists the programmable parameters of SM 322; DO 8 x DC 24 V/0.5 A,
including defaults.The defaults apply if you have not set any parameters in STEP 7.Table 3- 28 Parameters of SM 322; DO 8 x DC 24 V/0.5 AParameters Range of values Default Parametertype
ScopeEnable• Diagnostics interrupt yes/no no dynamic ModuleReaction to CPU STOP Set substitutevalue (SSV)Hold last value (HLV)SSVDiagnostics• Wirebreak• No load voltage L• Short-circuit to M
Diagnostics messages of SM 322; DO 8 x DC 24 V/0.5 A
The table provides an overview of the diagnostic messages of
SM 322; DO 8 x DC 24 V/0.5 A
Table 3- 29 Diagnostics messages of SM 322; DO 8 x DC 24 V/0.5 A
Diagnostics message LED Scope of diagnostics programmableWire-break* SF Channel yesLoad voltage missing SF Channel yesShort-circuit to M SF Channel yesShort-circuit to L+ SF Channel yesExternal auxiliary voltage missing SF Module noInternal auxiliary voltage missing SF Module nFuse blown SF Module noWatchdog time-out SF Module noEPROM fault SF Module no
RAM fault SF Module no* The module detects a wire-break at a current < 1 mA.If configured accordingly, the
SF LED and corresponding channel error LED light up when a wire-break is detected.
Prerequisite for the detection of errors indicated by programmable diagnostic messages is
an appropriate configuration of the digital module in STEP 7.
3.29 Digital output module SM 322; DO 8 x DC 24 V/ 0.5 A; with diagnostics interrupt; (6ES7322-8BF00-0AB0)
Module data
180 Manual, 06/2017, A5E00105505-AJCauses of error and troubleshootingTable 3- 30 Diagnostic messages of SM 322; DO 8 x DC 24 V/0.5 A, causes of error and troubleshooting
Diagnostics message Error detectioncondition ..Possible cause of error To correct or avoid errorWirebreak Only when output= "1"
Wire-break between the moduleand actuatorConnect the cableChannel not connected (open) Disable the "wire-break diagnostics"
parameter for the channel inSTEP 7
Load voltage missing Only when output
= "1"
Defective output Replace the module
Short-circuit to M Only when output
= "1"Overload at output Eliminate overloadShort-circuit of output to M Eliminate the short-circuitShort-circuit to L+ generally Short-circuit at output to L+ of themodule power supplEliminate the short-circuitExternal auxiliary voltagemissinggenerally Power supply L+ to module missingFeed supply L+Internal auxiliaryvoltagemissinggenerallyPower supply L+ to module missing Feed supply L+Fuse blown in module Replace themoduleFuse blown generally Fuse blown in module Replace the moduleWatchdog timeout generally Infrequent high electromagneticinterferenceEliminate the interference
Defective module Replace the moduleEPROM fault generally Infrequent high electromagneticinterference
Eliminate interference and cyclethe power supply of CPU off/on.
Defective module Replace the moduleRAM fault generally Infrequent high electromagnetic
interferenceEliminate interference and cycle
the power supply of CPU off/on.Defective module Replace the moduleFailure of the power supply to SM 322; DO 8 x DC 24V/0.5 A is always indicated at themodule's SF LED.This information is also available on the module (entry in diagnostics
data.)Triggering of diagnostics interrupts is determined by the parameter settings (see the nextchapter Interrupts of SM 322; DO 8 x DC 24/0.5 A (Page 182)).Properties of SM 322; DO 8 x DC 48-125V/1.5 A:● 8 outputs, with reverse polarity protection, andelectrically isolated in groups of 4● Output current 1.5 A