Place of Origin: | Japan |
Brand Name: | Tamagawa |
Certification: | CE |
Model Number: | TS2641N31E64 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 100pcs/week |
TAMAGAWA: | TAMAGAWA | Material: | Iron |
---|---|---|---|
Color: | Black | Temperature: | 20-90 |
Dimension: | 70mm | Wire: | Wire |
TS2641N31E64: | TS2641N31E64 |
TS2641N31E64
Communication via Ethernet/PROFINETCommunication via PROFIBUS | Web server, technology functions, |
Communication via PROFIBUS | system diagnostics, protection functions integrated |
HMI communication | When using an F-CPU: Safety mode provides you with a variety of CPUs that can be integrated. You can expand |
Guang Zhou Lai Jie Electric Co.,LTD
Please contact with “Tommy” for the price
TS5210N53
TS5320N510
TS5000N632
TS5212N510
TS5213N510
TS5312N616
TS208N101
TS5208N130
TS5213N530
TS5013N68
TS5214N566
TS5200N500
TS5305N616
TS5669N220
TS5214N564
TS5246N158
TS5667N650
TS5213N551
TS5668N20
TS5667N120
TS5667N420
TS5246N160
TS5312N512
TS5208N122
TS5641N151
TS5270N15
TS5308N616
TS5213N510
TS2014N181E32
TS5308N616
TS3462N1E76
TS5214N561
TS5214N510
TS2014N182E32
TS3653N2E5
TS5320N510
TS5016N-60
TS5016N60
TS2651N111E78
TS2014N181E32
TS2651N131E78
TS2651N141E78
TS5214N566
TS5205N450
TS5308N616
TS3462N1E76
48-2500P8-L6-5V
TS5214N561
TS5214N510
TS2014N182E32
TS3653N2E5
TS5320N510
TS5016N-60
TS5016N60
TS2651N111E78
TS2014N181E32
TS5013N60,
TS5013N61,
TS5016N60,
TS5017N60,
TS5013N68,
TS5
013N69
TS5013N60
TS5016N60
TS5013N60
TS5016N60
TS5017N60
TS5013N68
TS5013N69
TS2014N181E32
TS2014N311E32
TS2650N11E78
TS2650N1E78
TS5081N1
TS5084N250
TS5314N255
TS5303N510
TS5622N131
TS1616N200
TS1501N13
each CPU with I/O, communications and technology modules. If the memory and performance of a
CPU 1511-1 PN, for example, are sufficient for you, simply expand this with communication
modules for PROFIBUS and PROFINET. For technology functions, technology modules are
available in addition to compact CPUs.
The CPU provides you with the following options: Code work memory: Volatile memory that contains runtime-relevant parts of the program code.
Data work memory: Volatile memory that contains the runtime-relevant parts of the data blocks and
technology objects. For fail-safe operation of your plant, program the F-CPUs of the . Use the
"STEP 7 Safety Advanced" option package of the TIA Portal for this purpose. In combination with
the TIA Portal, the F-CPUs offer optimal integration of fail-safe systems:
• Integration of safety technology
• Instructions approved by German Technical Inspectorate for frequently required safety
applications
• Integration of safety functions up to SIL 3 according to IEC 62061 and/or PL e according to EN
ISO 13849-1
• Uniform engineering for standard and safety automation
• Simple documentation of changes
• Support in the acceptance of the safety program and no renewed acceptance of the safety
program after changes in the standard programTo set up secure networks, the automation system offers an integrated security
concept from authorization levels up to block protection:
Degree of protection Description
Access protection Protection against unauthorized configuration changes through four
authorization levels and integrated firewall
Know-how protection Protection against unauthorized access and modifications to algorithms by
means of password protection
Copy protection Protection against duplication of programs by linking individual blocks with the
serial number of the original memory card on the memory card
Locking the CPU Protection against unauthorized access by locking the front cover with a seal or
a lockIntegrated diagnostics across all levels of the automation is incorporated in the
automation system. All products have integrated diagnostic functions which you can use
to detect and remedy faults.
A uniform display concept ensures that error messages in the TIA Portal, on the HMI, the Web
server and in the display of the CPU are visualized identically as plain text informationMonitoring functions are integrated in the hardware as standard.
Diagnostics is implemented system-wide across bus limits.
Output of the cause of the error in plain text, archiving and logging of alarms
Automatic localization of the error source
Configurability of alarms
Plant-wide, uniform display of system status
Faults in the plant are immediately detected and reported on the display devices, even in STOP
mode. As a result, system diagnostics is always consistent with the actual state of the plantAn interface module connects the I/O devices as ET 200MP distributed I/O
system via PROFINET or PROFIBUS with the controller. The I/O modules form the interface between the controller and the process. The controller detects
the current process state via the connected sensors and actuators, and triggers the corresponding
reactions.
Digital and analog modules provide the inputs/outputs that are required
for the respective task.
The input/output modules are divided into function classes.The table below shows selected properties and technical specifications of different function classes
of input/output modules.Special modules for extremely fast
applications
Shortest input delays
Shortest conversion times
Isochronous mode
High Feature (HF) Flexible use
Even for complex applications
Parameters for each channel
Diagnostics for each channel
Add-on functions
With analog modules
• Highest accuracy (<0.1%)
• High common-mode voltage, single
channel isolation if necessary