Home Products

Megger

All Products
Bently Nevada (1489)
TYCO (179)
TAMAGAWA (1899)
Leine linde (922)
BAUMUELLER (1766)
ProvibTech (206)
AMETEK (132)
SCHALTBAU (179)
Megger (108)
UE system (57)
CARBOLITE (415)
metrel (90)
Druck (103)
Unitronics (116)
Sumtak (651)
Avtron (231)
KOYO (365)
Koehler (122)
HEIDEHAIN (426)
I'm Online Chat Now

Megger

(108)
China LENZE EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV factory

LENZE EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV EVF9337-EV

voltage/current output range. See "Valid substitute value for the output range" table in the section Structure of a data record for output channels of the analog on-board I/O (Page 154)The diagnostics for short ... Read More
2018-12-27 15:18:56
China LENZE EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV factory

LENZE EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV EVF9336-EV

Short-circuit has occurred (only for the "Voltage" output type)The addresses are divided into 16 digital input channels and 16 digital output channels. STEP 7 (TIA Portal) assigns the addresses automatically. ... Read More
2018-12-27 15:15:28
China LENZE EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV factory

LENZE EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV EVF9333-EV

and outputs to the pulse duration modulation (PWM) and the pulse train output (PTO) during the device configuration. If you assign digital inputs and outputs to these functions, the values of the addresses of ... Read More
2018-12-27 15:06:51
China LENZE EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV factory

LENZE EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV EVF9332-EV

At the digital outputs, each of the ground connections of the loads is connected with a eparate cable for each load to the central terminal block. With correct wiring, the supply current flows from the power ... Read More
2018-12-27 15:03:35
China LENZE EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV factory

LENZE EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV EVF9331-EV

sensors or thermal resistors at the channel available for this (channel 4). Note3-wire connection Note that line resistances are not compensated with a 3-wire connection.The following figure 3-wire connection ... Read More
2018-12-27 11:47:31
China LENZE EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV factory

LENZE EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV EVF9330-EV

User sets MODE_SLOT to 1 • User sets LD_SLOT to the required value (1 for period duration) User changes value in SLOT continuously and technology channel evaluates continuously Value in SLOT exceeds permitted ... Read More
2018-12-27 11:44:03
China LENZE EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV factory

LENZE EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV EVF9329-EV

SET_DQA ● If 1, set the output A to 1, if TM_CTRL_DQ is inactive If 0, set the output A to 0, if TM_CTRL_DQ is inactive RES_ERROR Resetting the error bit memory ERR_LD in the feedback interfaceSLOT has the ... Read More
2018-12-27 11:38:15
China LENZE EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV factory

LENZE EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV EVF9328-EV

output (DQA) of a pulse generator directly via the control program. Select the function for th DQ direct control by deleting the output control bit of the PWM channel (TM_CTRL_DQ = 0) in the control interface. ... Read More
2018-12-27 11:32:30
China LENZE EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV factory

LENZE EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV EVF9327-EV

Count up for "PTO (Countup (A) and Countdown (B))" The "Clock generatorforward (A)" parameter defines the hardware voutput for PTO signal A. [Output address DQ for PTO signal A (output frequency 100 kHz)] ... Read More
2018-12-27 11:28:57
China LENZE EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004 factory

LENZE EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004 EVF9326-EVV004

No supply voltage L+ With the parameter "Missing supply voltage L+", ou activate the diagnostic interrupt of the channel in the event of no supply voltage L+. Deactivated Deactivated Activated Data exchange ... Read More
2018-12-27 11:21:09
Page 6 of 11|< 1 2 3 4 5 6 7 8 9 10 >|