Home Products

Megger

All Products
Bently Nevada (1489)
TYCO (179)
TAMAGAWA (1899)
Leine linde (922)
BAUMUELLER (1766)
ProvibTech (206)
AMETEK (132)
SCHALTBAU (179)
Megger (108)
UE system (57)
CARBOLITE (415)
metrel (90)
Druck (103)
Unitronics (116)
Sumtak (651)
Avtron (231)
KOYO (365)
Koehler (122)
HEIDEHAIN (426)
I'm Online Chat Now

Megger

(108)
China LENZE E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354 factory

LENZE E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354 E94ASSE6354

time of 20 ms. The analog on-board I/O supplies a measured value to the CPU every millisecond within the integration timeThe following figure shows how this works using a 10 Hz interference frequency suppressio... Read More
2018-12-25 15:48:24
China LENZE E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724 factory

LENZE E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724 E94ASSE5724

assigned as follows: ● Data record 0 for channel 0 ● Data record 1 for channel 1 Data record 14 for channel 14 ● Data record 15 for channel 15 Data record structure The figure below shows the structure of data ... Read More
2018-12-25 15:41:18
China LENZE E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604 factory

LENZE E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604 E94ASSE4604

8; in total over all interfaces • Number of IO devices per tool, max. 8 sochronous operation (application synchronized up to terminal) Update times Minimum value of update time also depends on the communication ... Read More
2018-12-25 15:34:11
China LENZE E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924 factory

LENZE E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924 E94ASSE2924

New Capture value present1) 8 When the current counter or position value is saved as a Capture value, the technology function triggers a hardware interrupt in the CPU. Synchronization of the counter by an ... Read More
2018-12-25 15:30:33
China LENZE E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454 factory

LENZE E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454 E94ASSE2454

se a different encoder type or modify the wiring, for example, using cables with larger cross-section Interruption of the cable between the analog on-board I/O and sensor Connect the cable Channel not connected ... Read More
2018-12-25 15:22:30
China LENZE E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024 factory

LENZE E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024 E94ASSE2024

RUN/STOP, ERROR and MAINT LEDs.Each port has a LINK RX/TX LED. The table below shows the various "LED scenarios" of There is no Ethernet connection between the PROFINET interface of the PROFINET device and the ... Read More
2018-12-25 15:16:56
China LENZE E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724 factory

LENZE E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724 E94ASSE1724

records 0 to 4) if all other input channels are disabled. able 5- 7 Configurable "Hardware interrupt" parameters Parameters 1) Value range Default Reconfiguration in RUN Hardware interrupts rdware interrupt low ... Read More
2018-12-25 14:55:01
China LENZE E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454 factory

LENZE E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454 E94ASSE1454

diagnostics option. You activate the use of the value status in the hardware configuration of When you activate the value status, the input area of the digital on-board I/O (X11/X12) contains four additional ... Read More
2018-12-25 14:45:58
China LENZE E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864 factory

LENZE E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864 E94ASSE0864

The encoder or sensor switches the A, B and N inputs to 24 V DC. Note External load resistance Note that, depending on the characteristics of the signal source, effective load and height of the signal frequency... Read More
2018-12-25 12:10:43
China LENZE E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474 factory

LENZE E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474 E94ASSE0474

resistance-type sensors or thermal resistors at the channel available for this (channel 4). Equotential bonding cable (optional) ⑥ 3-wire connection 3-wire connection Note that line resistances are not ... Read More
2018-12-25 11:52:30
Page 10 of 11|< 2 3 4 5 6 7 8 9 10 11 >|